Related Experiment Video
Updated: Aug 22, 2026

Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
Published on: February 6, 2019
Neutron spectra in a tissue equivalent phantom during photon radiotherapy treatment by LINACS
Abstract:
Bremsstrahlung photon beams produced by LINAC accelerators are currently the most used radiotherapy method for tumour treatments. When the photon energy exceeds the (gamma,n) reaction threshold energy, the patient receives an undesired dose due to photoneutron production both in the accelerator head and in the human body. In this paper, a method is presented for the assessment of the photoneutron spectra produced by Giant Dipole Resonance (GDR) during cancer radiotherapy with energetic photon beams. Experimental and numerical results have been obtained for the facility at Onkologik Klinik, Lund (Sweden), which is based on an ELEKTA 18 MV LINAC. Neutron spectra are evaluated both at the patient plane and inside an anthropomorphic phantom.
More Related Videos
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy (PRRT): 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
06:42Plasmonic Photothermal Cancer Therapy: Nanoparticle-embedded Tumor-tissue-mimicking Phantoms for Visualizing Photothermal Temperature Distribution
Published on: May 9, 2025
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...