On-column derivatization-capillary electrochromatography with o-phthalaldehyde/alkylthiol for assay of biogenic
Shigeyuki Oguri1, Yuko Maeda, Aki Mizusawa
1Laboratory of Food Science, Department of Home Economics, Aichi-Gakusen University, 28 Kamikawanari, Hegoshi-Cho, Okazaki City 444-8520, Japan. s-oguri@gakusen.ac.jp
Abstract:
The elution behaviors of the biogenic amines, histamine (HA) and its metabolite methyl histamine (MHA), were evaluated by means of on-column derivatization (OCD)-capillary electrochromatography (CEC) which employed a monolithic octadecylsilica (ODS) capillary column (20 cm of effective length x 50 microm of inner diameter). Five kinds of alkylthiols, e.g., 2- hydroxyethylthiol (or 2-mercaptoethanol (2-ME)), ethanethiol (ET), 1-propanethiol (1-PT), 2-methyl-1-propanethiol (2-MPT) and 1-butanethiol (1-BT) were separately presented at 5 mM each in the OCD-CEC separation run buffer consisting of 60% acetonitrile in 5 mM o-phthalaldehyde (OPA)-10 mM borate buffer (pH 10). When 2-ME was present in the run buffer solution, both derivatives corresponding to HA and MHA migrated separately, but closely together through the capillary column. Replacement of 2-ME with 1-BT in the run buffer solution caused a delay in their elution profiles on the electrochromatogram and the separation between those two peaks became remarkably improved. The elution times of HA and MHA followed the increase in alkyl chain length or hydrophobicity of thiol, 1-BT > 2-MPT > 1-PT > ET > 2-ME. Performance of on-line preconcentrations of HA and MHA was also evaluated by varying the electrokinetic injection voltage from 1 kV to 8 kV. The peak area counts corresponding to HA recorded about 50 times higher when 2 kV was applied for 240 s to a 0.1 mM HA solution than when 8 kV was applied for 5 s. This method was next applied to a sample of human urine spiked with HA and MHA at levels of 0.1 microM each. Although HA and MHA peaks were not identifiable among the peaks corresponding to the materials in the urine matrix when OPA/2-ME was employed in a run buffer for the OCD-CEC, the separation and identification of their peaks became possible by replacing 2-ME with 1-BT in the run buffer solution.
More Related Videos
13:35A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
12:47Workflow Based on the Combination of Isotopic Tracer Experiments to Investigate Microbial Metabolism of Multiple Nutrient Sources
Published on: January 22, 2018
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
Principles Of Column Chromatography