Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
An alternative approach for the estimation of equivalent temperature in gas chromatography
Kornkanok Aryusuk1, Dararat Yensruang, Kanit Krisnangkura
1Biochemical Technology Division, School of Bioresources and Technology, King Mongkut's University of Technology Thonburi. Toongkru, Bangkok 10140 Thailand.
Abstract:
The temperature at which the isothermal retention time (tRiso) is equal to the temperature-programmed retention time (tRTPGC) or the isothermal retention index (Iiso) is equal to the temperature-programmed retention index (ITPGC) is defined as the equivalent temperature (Teq). The Teq of one-, two-, three-, and four-step temperature-programmed gas chromatography (TPGC) of unsaturated fatty acid methyl esters (FAMEs) from Chinese mustard seed oil is calculated. All of the tR values obtained at the Teq (tRTeq) are very close to the tRTPGC. The highest difference for each chromatogram is less than 0.5%. The slight deviation may partly arrive from the difficulty in setting the desired carrier gas flow rate. Also, good agreement among equivalent chain length values determined by different methods is observed, including the graphical method at the Teq. Therefore, it is speculated that the proposed method may facilitate the GC identification of FAMEs as well as other organic compounds in TPGC by using the available isothermal retention index database.
More Related Videos
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
06:51Quantitative Analysis by Thermogravimetry-Mass Spectrum Analysis for Reactions with Evolved Gases
Published on: October 29, 2018
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Types of Detectors-II