Related Experiment Video
Updated: Aug 22, 2026

Isolation of Adeno-Associated Viral Vectors Through a Single-Step and Semi-Automated Heparin Affinity Chromatography Protocol
Published on: April 5, 2024
Determination of the new HIV-protease inhibitor atazanavir by liquid chromatography after solid-phase extraction
S Colombo1, N Guignard, C Marzolini
1Division de Pharmacologie clinique, Département de Médecine, Laboratoire BH 18-218, Centre Hospitalier Universitaire Vaudois, 1011 Lausanne, CHUV, Switzerland.
Abstract:
An HPLC method previously described for the simultaneous assay of amprenavir, ritonavir, indinavir, saquinavir, nelfinavir and efavirenz is proposed here for the simultaneous analysis of the new HIV protease inhibitor atazanavir (ATV) in human plasma, by off-line solid-phase extraction (SPE) followed by HPLC coupled with UV-diode array detection. After viral inactivation by heat (60 degrees C for 60 min), plasma (600 microl) with clozapine (internal standard) is diluted 1 + 1 with phosphate buffer pH 7 and subjected to a SPE on a C18 cartridge. Matrix components are eliminated with 2 x 500 microl of a solution of 0.1% H(3)PO(4) neutralised with NaOH to pH 7. ATV is eluted with 3 x 500 microl MeOH. The resulting eluate is evaporated under nitrogen at room temperature and is reconstituted in 100 microl MeOH/H(2)O 50/50. A 40 microl volume is injected onto a Nucleosil 100-5 microm C18 AB column. ATV is analysed by UV detection at 201 nm using a gradient elution program with solvents constituted of MeCN and phosphate buffer adjusted to pH 5.14. The mobile phase also contains 0.02% sodium heptanesulfonate, enabling an excellent separation of ATV from the other HIV protease inhibitors (PIs) amprenavir, indinavir, saquinavir, ritonavir, lopinavir, nelfinavir and the non-nucleoside reverse transcriptase inhibitors (NNRTIs) efavirenz and nevirapine. The calibration curves are linear up to 10 microg/ml, with a lower limit of quantification of 0.2 microg/ml. The mean absolute recovery of ATV is 96.4 +/- 3.2%. The method is precise with mean inter-day CVs within 1.1-6.1%, and accurate (range of inter-day deviations +0.3 to +2.3%). The method has been validated and is currently applied to the monitoring of ATV in HIV patients.
More Related Videos
10:33Development of Inhibitors of Protein-protein Interactions through REPLACE: Application to the Design and Development Non-ATP Competitive CDK Inhibitors
Published on: October 26, 2015
09:38Identification of Nucleolar Factors During HIV-1 Replication Through Rev Immunoprecipitation and Mass Spectrometry
Published on: June 26, 2019
Related Concept Videos
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Elution Process