Published on: January 24, 2025
Diaphragm electromyogram root mean square response to hypercapnia and its intersubject and day-to-day variation
Bhajan Singh1, Janine A Panizza, Kevin E Finucane
1Dept. of Pulmonary Physiology, Sir Charles Gairdner Hospital, Hospital Avenue, Nedlands, WA 6009, Australia. Bhajan.Singh@health.wa.gov.au
Abstract:
Diaphragm activation can be quantified by measuring the root mean square of crural EMG (RMSdi) (Beck J, Sinderby C, Lindstrom L, and Grassino A, J Appl Physiol 85: 1123-1134, 1998). To examine intersubject and day-to-day variation in the RMSdi-Pco(2) relationship, end-tidal Pco(2), minute ventilation (Ve), respiratory frequency (f(B)), and RMSdi were measured in seven healthy subjects on two occasions during steady-state ventilation at seven levels of inspired O(2) fraction (Fi(CO(2))) from 0 to 0.08 in random order. RMSdi was measured with a multielectrode esophageal catheter and controlled for signal contamination and diaphragm position. RMSdi was normalized for values obtained during quiet breathing at functional residual capacity, at Fi(CO(2)) of 0.04, and during an inspiratory capacity maneuver (RMSdi%max) as well as ECG R-wave amplitude at functional residual capacity (RMSdi/ECG(R)), f(B), and thickness of the costal diaphragm measured by ultrasound. RMSdi increased linearly with Pco(2) (mean r(2) = 0.83 +/- 0.10); at the highest Fi(CO(2)), RMSdi%max was 40.2 +/- 11.6%. Relative to the intersubject variation in the Ve-Pco(2) relationship, intersubject variations in the slopes and intercepts of the RMSdi-Pco(2) relationships were 1.7 and 1.8 times, respectively, and RMSdi%max-Pco(2) relationships 0.9 and 1.3 times, respectively, and were unrelated to f(B) and diaphragm thickness. Relative to the day-to-day variation in the Ve-Pco(2) relationship, day-to-day variation in the slopes and intercepts of the RMSdi-Pco(2) relationships were 2.8 and 4.4 times, respectively, and RMSdi/ECG(R)-Pco(2) relationships 1.3 and 2.2 times, respectively. It was concluded that the RMSdi-Pco(2) relationship measures chemosensitivity and is best compared between subjects via RMSdi%max and on separate occasions in the same subject via RMSdi/ECG(R).
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Acute Respiratory Failure-III
Alterations in Respiration II
In Biot's breathing, the respiratory rate and depth are irregular, alternating between periods of deep gasping and apnea. Common causes include...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Respiratory Volumes and Capacities I
Respiratory System Abnormal Finding I: Inspection and Percussion
Inspection Findings
During an inspection, several findings may suggest the presence of respiratory distress or disease. Pursed-lip breathing, where exhalation is slowed by...