Aortoiliac gadolinium-enhanced CT angiography: improved results with a 16-detector row scanner compared with a
Stephan Wicky1, Alan Greenfield, Chieh-Min Fan
1Department of Radiology, Massachusetts General Hospital and Harvard Medical School, 55 Fruit Street, Boston, MA 02114, USA. swicky@partners.org
Purpose:
To assess the level of vascular enhancement of gadolinium-enhanced aortoiliac computed tomographic (CT) angiography with a 16-detector row CT scanner and to compare it with the results of previous similar studies that used four-detector row CT units.
Materials And Methods:
Eleven gadolinium-enhanced CT angiograms were obtained in 10 consecutive patients with contraindication to iodinated contrast medium with use of a 16-detector row CT scanner. In the region of interest, attenuation measurements (in HU) were obtained from the proximal abdominal aorta to the common femoral arteries during unenhanced, gadolinium-enhanced, and delayed acquisitions. The results were compared to those in the 15 consecutive patients who most recently had similar examinations performed on a four-detector row CT unit. Phantom studies with diluted gadolinium were conducted to compare attenuation between CT units.
Results:
On four-detector row CT, throughout the scan length, mean enhancement values were 53.8 HU +/- 5.3 and 15.0 HU +/- 2.6 for gadolinium-enhanced and delayed series, respectively. For the 16-detector row CT unit, they were 76.1 HU +/- 3.4 and 21.3 HU +/- 1.3, respectively. As a result of a shorter scan time and a more optimal start time, the 16-detector row CT unit provided significantly greater and more consistent enhancement throughout the scan length compared with the four-detector row CT unit (P =.0106). Similar structures had significantly greater enhancement when 120 kV was applied instead of 140 kV (P =.0495)
Conclusion:
The 16-detector row CT scanner improved gadolinium-enhanced CT angiography results compared with the four-detector row CT unit.
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies VII: Vascular Imaging
Imaging Studies for Cardiovascular System IV: CMRI
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...