Comparing office-based and ambulatory blood pressure monitoring in clinical trials
W M Vollmer1, L J Appel, L P Svetkey
1Kaiser Permanente Center for Health Research, Portland, OR 97227-1110, USA. william.vollmer@kpchr.org
Abstract:
Ambulatory blood pressure monitoring (ABPM) is commonly used in clinical trials. Yet, its ability to detect blood pressure (BP) change in comparison to multiple office-based measurements has received limited attention. We recorded ambulatory and five daily pairs of random zero (RZ) BPs pre- and post-intervention on 321 adult participants in the multicentre Dietary Approaches to Stop Hypertension trial. Treatment effect estimates measured by ambulatory monitoring were similar to those measured by RZ and did not differ significantly for waking vs 24-h ambulatory measurements. For systolic BP, the standard deviations of change in mean 24-h ambulatory BP (8.0 mmHg among hypertensives and 6.0 mmHg among nonhypertensives) were comparable to or lower than the corresponding standard deviations of change in RZ-BP based on five daily readings (8.9 and 5.9 mmHg). The standard deviations of change for mean waking ambulatory BP (8.7 and 6.7 mmHg) were comparable to those obtained using three to four daily RZ readings. Results for diastolic BP were qualitatively similar. Ambulatory monitoring was more efficient (ie, a smaller sample size could detect a given BP change) than three to four sets of daily RZ readings and required fewer clinic visits. The average of 33 ambulatory BP readings during the waking hours had an efficiency comparable to that from the mean of four daily pairs of RZ-BPs. Participants readily accepted the ABPM devices, and their use requires less staff training. ABPM provides a useful alternative to RZ-BP measurements in clinical trials.
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Errors occurring during blood pressure monitoring
Several factors...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pre-Procedural Guidelines for Assessing Blood Pressure
Measurement of Blood Pressure