Retention indexes for temperature-programmed gas chromatography of polychlorinated biphenyls
1Department of Environmental Health and Toxicology, School of Public Health, State University of New York at Albany, Albany, New York 12201-0509, USA.
Abstract:
A noninteger retention index was defined based on a series of PCB internal standards, namely congeners 8 (2,4'-dichlorobiphenyl), 31 (2,4',5-trichlorobiphenyl), 44 (2,2',3,5'-tetrachlorobiphenyl), 101 (2,2',4,5,5'-pentachlorobiphenyl), 138 (2,2',3,4,4',5'-hexachlorobiphenyl), 180 (2,2',3,4,4',5,5'-heptachlorobiphenyl), and 194 (2,2',3,3',4,4',5,5'-octachlorobiphenyl). These retention index markers are common congeners present in technical mixtures and most environmental samples, and they show a linear dependence of retention time on the number of chlorine atoms, in the temperature-programmed analysis. The index values are calculated with a single regression equation instead of the Van den Dool and Kratz equation. The retention indexes of all 209 PCBs on two commonly used columns (DB-XLB and DB-5), as well as on a supplementary column of DB-17 in capillary gas chromatography, were determined using this system. The reliability of the retention index is quite good, with the average 95% confidence limits for three measurements on each PCB being +/-0.1 index unit under the same chromatographic conditions and +/-0.4 index unit under different column head pressures. The effect of heating rate of the programmed runs on the retention index was also investigated. The inversion of the elution order of some congener pairs on the DB-XLB column for different temperature heating rates was observed. Our index values were compared with those of Castello and Testini.
More Related Videos
08:12Characterization, Quantification and Compound-specific Isotopic Analysis of Pyrogenic Carbon Using Benzene Polycarboxylic Acids (BPCA)
Published on: May 16, 2016
10:14Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Related Concept Videos
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Types of Detectors-II
Chromatographic Methods: Terminology
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...