Point-Of-Care Ultrasound Screening for Proximal Lower Extremity Deep Venous Thrombosis
Published on: February 10, 2023
Change in thrombus length on venous ultrasound and recurrent deep vein thrombosis
Lori-Ann Linkins1, Patricia Pasquale, Sharon Paterson
1Department of Medicine, McMaster University. llinkins@thrombosis.hhscr.org
Background:
Despite successful treatment, deep vein thrombosis may not fully resolve in some patients. Consequently, in patients with new symptoms in a previously affected leg, noncompressibility on ultrasound cannot be assumed to be due to recurrent thrombosis; therefore, we sought to determine interobserver agreement on ultrasound measurements of thrombus length and identify the change in length that is likely to indicate thrombus extension.
Methods:
Cross-sectional study of patients with previous proximal deep vein thrombosis and residual ultrasound abnormalities, but without symptoms suggestive of recurrence. The patients had a standardized series of measurements of thrombus length independently performed by 2 ultrasonographers. The outcome measure was the agreement between the ultrasonographers on the distance of thrombus margins from 4 anatomical landmarks.
Results:
There was good interobserver agreement on thrombus length when measured from the saphenofemoral junction, mid-popliteal fossa, and mid-patella (93% or more of the variance was accounted for by the paired measurements). Using these landmarks, the 95th percentile for the absolute difference between paired measurements was 8.9 cm for the saphenofemoral junction, 8.5 cm for the mid-popliteal fossa, and 8.4 cm for the mid-patella.
Conclusions:
When 2 ultrasound examinations are compared, an apparent increase in thrombus length of 9 cm or greater is likely to be supportive of a diagnosis of recurrent deep vein thrombosis. Increases in thrombus length of less than 9 cm appear to be within the bounds of measurement error.
Related Concept Videos
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Venous Thrombosis I: Introduction
Venous Thrombosis III: Interprofessional Care
Varicose Veins II: Diagnostic Studies and Interprofessional Care
Venous Thrombosis IV: Nursing Management
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...