Related Experiment Video
Updated: Aug 22, 2026

Monitoring Lung Function with Electrical Impedance Tomography in the Intensive Care Unit
Published on: September 6, 2024
Assessment of physiologic variables and subjective comfort under different levels of pressure support ventilation
Michele Vitacca1, Luca Bianchi, Ercole Zanotti
1Lung Function and Respiratory Intermediate Intensive Care Unit, S. Maugeri Foundation IRCCS-Medical Center of Gussago, Via Pinidolo 23 25064 Gussago (Brescia), Italy. mvitacca@fsm.it
Study Objectives:
To evaluate the effects of 12 ventilator settings (pressure support ventilation [PSV] plus positive end-expiratory pressure [PEEP], 30 + 0 cm H(2)O; 25 + 5 cm H(2)O; 25 + 0 cm H(2)O; 20 + 5 cm H(2)O; 20 + 0 cm H(2)O; 15 + 5 cm H(2)O; 15 + 0 cm H(2)O; 10 + 5 cm H(2)O; 10 + 0 cm H(2)O; 5 + 5 cm H(2)O; 5 + 0 cm H(2)O; and 0 + 5 cm H(2)O) on physiologic variables; the percentage of ineffective efforts; patient comfort; and whether the diagnosis of COPD may influence results.
Design:
Prospective, randomized, physiologic study.
Setting:
Three weaning centers.
Patients:
Thirty-six consecutive patients (20 patients with COPD).
Intervention:
Patients were randomly submitted to the 12 settings.
Measurements And Results:
Breathing pattern, respiratory drive (p0.1), arterial oxygen saturation (Sato(2)), heart rate, percentage of ineffective efforts per minute, patient comfort measured by means of a visual analogue scale (VAS), and BORG scale were recorded under each setting. Under different levels of assistance, breathing pattern, Sato(2), and p0.1 significantly and linearly changed (p < 0.0001) while VAS and BORG scale presented a significant (p = 0.027) U-shaped trend; high or low assistance caused the most discomfort. Under high levels of assistance, a higher (analysis of variance, p = 0.023) frequency of ineffective effort percentage was observed in the subgroup of 26 patients who presented this phenomenon. Breathing pattern significantly (p = 0.013) changed when compared to PSV alone (PSV plus zero end-expiratory pressure [ZEEP]) at the same total inspiratory pressure assistance (PSV plus PEEP). A huge variability among patients in breathing pattern and comfort was found under the setting rated as the most comfortable by patients. The diagnosis of COPD did not influence the overall results.
Conclusions:
The following conclusions are made: (1) physiologic variables followed a linear trend, while comfort followed a U-shaped trend under different levels of PSV (irrespective of COPD diagnosis); (2) high assistance caused an increase in ineffective efforts; (3) only the breathing pattern significantly changed when total assistance was given as PSV plus PEEP when compared to PSV alone (PSV plus ZEEP); and (4) the extreme levels of PSV are not associated with the best comfort.
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Mechanical Ventilation I: Indication and Settings
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...