Related Experiment Video
Updated: Aug 22, 2026

Quantification of Levator Ani Hiatus Enlargement by Magnetic Resonance Imaging in Males and Females with Pelvic Organ Prolapse
Published on: April 17, 2019
Longitudinal study of Pelvicol pubovaginal slings using magnetic resonance imaging
J W Barrington1, M Abdel-Fattah, A S Arunkalaivanan
1Department of Obstetrics and Gynaecology, Torbay Hospital, Torquay, Devon, UK.
Abstract:
The mechanism of urinary continence is complicated and is poorly understood. One current opinion is that there is an absence or weakness of the endopelvic fascial supports of the urethra. Pubovaginal slings are rapidly becoming the surgical procedure of choice in the management of urodynamic stress incontinence but their method of action is unclear. This study using magnetic resonance imaging shows how a pubovaginal sling can restore the normal anatomy and continence and adds to the global understanding of this condition.