Related Experiment Video
Updated: Aug 22, 2026

Functional Assessment of Intestinal Motility and Gut Wall Inflammation in Rodents: Analyses in a Standardized Model of Intestinal Manipulation
Published on: September 11, 2012
Effect of oral purgatives on gastric and small bowel transit time in capsule endoscopy
Zvi Fireman1, Yael Kopelman, Lev Fish
1Departments of Gastroenterology, Hillel Yaffe Medical Center, Hadera, Israel. fireman@hillel-yaffe.health.gov.il
Background:
During ingestible capsule endoscopy, video images are recorded throughout the device's natural propulsion through the digestive system. Shortening the transit time of the wireless video capsule through the stomach and small bowel could reduce the time needed to read and analyze the resultant images, utilize more effectively the short life of the capsule battery (7 +/- 1 hours) and make it possible to image the entire small bowel.
Objective:
To measure gastric and small bowel transit times, with and without preparation, using capsule endoscopy.
Methods:
Capsule transit times through the stomach, small bowel and colon were evaluated by analysis of the videos generated during the capsule's passage. The study group included 62 patients with small and large bowel pathologies (e.g., iron deficiency anemia, Crohn's disease). The patients were divided into three groups: prepared with polyethylene glycol (Group A, n = 9), prepared with sodium phosphate (Group B, n = 13), and with no preparation (Group C, n = 40).
Results:
The gastric emptying times were 20.4 +/- 15.2 minutes in group A, 55.7 +/- 45.1 in group B, and 48.3 +/- 28.7 in group C (P = 0.01). The capsule produced views of the cecum in only 49 of the 62 patients. The mean small bowel transit time for these 49 patients was 238.8 +/- 82.1 minutes, making the mean times for the groups (A,B,C) 148.9 +/- 32.6, 289.4 +/- 77.2 and 249.3 +/- 73.9 minutes respectively (P = 0.0001).
Conclusion:
Compared to both SP and no preparation, preparation of the colon with PEG significantly shortened the transit time of the capsule through the stomach and small bowel.
Related Concept Videos
Endoscopic Procedures III: Video Capsule Endoscopy
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and solid...
Drugs Affecting GI Tract Motility: Other Laxatives
Osmotic or saline laxatives, like magnesium hydroxide or milk of...
Drugs Affecting GI Tract Motility: Bulk-Forming and Stimulant Laxatives
Bulk-forming laxatives, such as psyllium, methylcellulose, and polycarbophil, absorb water in the intestine, increasing stool bulk and promoting bowel movement. This makes...
Lower GI Series: Barium Enema
Procedure Details
The examination begins by inserting a lubricated rectal tube into the patient's rectum to administer a radiopaque barium solution. The barium flow is carefully...
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
