Related Experiment Video
Updated: Aug 22, 2026

Assessment of Child Anthropometry in a Large Epidemiologic Study
Published on: February 2, 2017
Thermal manikin measurements--exact or not?
Hannu Anttonen1, Juhani Niskanen, Harriet Meinander
1Oulu Regional Institute of Occupational Health, Oulu, Finland. Hannu.Anttonen@ttl.fi
Abstract:
According to the European prestandard ENV 342:1998, the thermal insulation of cold-protective clothing is measured with a thermal manikin. Systematic studies on the reproducibility of the values, measured with different types of clothing on the commonly used standing and walking manikins, have not been reported in the literature. Over 300 measurements were done in 8 different European laboratories. The reproducibility of the thermal insulation test results was good. The coefficient of variation was lower than 8%. The measured clothing should fit the manikin precisely, because poorly fitting clothing gave an error in the results. The correlation between parallel and serial insulation values was excellent and parallel values were about 20% lower than serial ones. The influence of ambient conditions was critical only in the case of air velocity. The reproducibility of thermal insulation test results in a single laboratory was good, and the variation was lower than 3%.
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...

