Related Experiment Video
Updated: Aug 22, 2026

Automated, High-resolution Mobile Collection System for the Nitrogen Isotopic Analysis of NOx
Published on: December 20, 2016
Determination of nitrate by suppressed ion chromatography after copperised-cadmium column reduction
J R E Thabano1, D Abong'o, G M Sawula
1Department of Chemistry, University of Botswana, Private Bag 0022, Gaborone, Botswana. thabano@mopipi.ub.bw
Abstract:
The nitrate-selective copperised-cadmium (Cu-Cd) reduction reaction coupled directly to the highly sensitive nitrite ion chromatographic detection, produced a more precise method for determination of nitrate than any one of the two conventional methods. A borate buffer solution used in the reduction reaction, in place of the conventional ammonium-EDTA buffer solution, eliminated interferences from co-eluting ions in the subsequent ion chromatographic detection of nitrite. Optimised experimental conditions included using a packed-bed Cu-Cd reductor column length of 12.5 cm, a solution flow rate of 3.0 ml/min, and using 10.0 ml of borate buffer solution for each 20.0 ml of nitrate-containing solution. Precision was high for results obtained within a greatly extended linear dynamic range of 0.006-1.20 mg/l NO3-, with a much lower limit of detection of 0.40 microg/l NO3-. Cu-Cd reductor column efficiency was 98.20+/-6.03%. Validation of the method was undertaken using certified reference materials. The method was successfully applied to analysis of dam water, river water and storm water samples, producing more precise results than either the conventional colorimetric method or the conventional ion chromatographic method.
More Related Videos
07:38A General Method for Detecting Nitrosamide Formation in the In Vitro Metabolism of Nitrosamines by Cytochrome P450s
Published on: September 25, 2017
08:05Measurement of the Potential Rates of Dissimilatory Nitrate Reduction to Ammonium Based on 14NH4+/15NH4+ Analyses via Sequential Conversion to N2O
Published on: October 7, 2020
Related Concept Videos
Precipitation Titration Curve: Analysis
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Precipitation Gravimetry
In determining nickel by gravimetric analysis, a precipitant of ethanolic dimethylglyoxime is added to a hot nickel salt solution. This is quickly followed by the dropwise addition of dilute ammonia solution until precipitation occurs. A...
Precipitation Titration: Overview
A precipitation titration curve demonstrates the change in concentration of the titrant or analyte upon adding the...
Electrodeposition
Electrodeposition can...
Qualitative Analysis