An electrospray ionization-tandem mass spectrometry method for identifying chlorinated drinking water disinfection
Xiangru Zhang1, Roger A Minear, Yingbo Guo
1Department of Civil and Environmental Engineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA. xzhang1@nd.edu
Abstract:
Identification of chlorinated drinking water disinfection byproducts (DBPs) was investigated by using electrospray ionization-mass spectrometry/mass spectrometry (ESI-MS/MS). Chlorine-containing compounds were found to form chloride ion fragments by MS/MS, which can be used as a 'fingerprint' for chlorinated DBPs. Instrumental parameters that affect the formation of chloride ions by ESI-MS/MS were examined, and appropriate conditions for use in finding specific structural information were evaluated. The results show that maximizing the formation of chloride ions by MS/MS required a relatively high collision energy and collision gas pressure; also, limiting the scan range to m/z 30-40 allowed improved sensitivity for detection; but obtaining structural information required the use of lower collision energies. The conditions obtained were demonstrated to be effective in identifying chlorinated DBPs in a standard sample with relatively low concentrations of each component and in a chlorinated humic substance sample. Sample pretreatment techniques including ultrafiltration and size exclusion chromatography appeared to be helpful for identifying highly polar or high molecular weight chlorine-containing DBPs by ESI-MS/MS.
More Related Videos
12:11A Modified EPA Method 1623 that Uses Tangential Flow Hollow-fiber Ultrafiltration and Heat Dissociation Steps to Detect Waterborne Cryptosporidium and Giardia spp.
Published on: July 9, 2012
05:46Identification of Pharmaceuticals in The Aquatic Environment Using HPLC-ESI-Q-TOF-MS and Elimination of Erythromycin Through Photo-Induced Degradation
Published on: August 1, 2018
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Tandem Mass Spectrometry
High-Performance Liquid Chromatography: Types of Detectors
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Gas Chromatography: Types of Detectors-II
Rapid Identification of Pathogens
