Related Experiment Video
Updated: Aug 22, 2026

Fluorescence Microscopy Methods for Determining the Viability of Bacteria in Association with Mammalian Cells
Published on: September 5, 2013
Mechanism and use of the commercially available viability stain, BacLight
12JS.012, Novozymes Fermentation Pilot Plant, Smørmosevej 25, 2880 Bagsvaerd, Denmark. stus@novozymes.com
Background:
BacLight (Molecular Probes, Eugene, OR, USA) is a popular fluorescence-based two-component stain for determining bacterial cell viability. The main purpose of this work was to fully elucidate the mechanism and to determine why it is sometimes reported that cells stain simultaneously live and dead.
Methods:
Solutions of DNA were stained with the two components, propidium iodide (PI) and SYTO9, in different combinations, and fluorescence spectra were collected.
Results:
K(PI) and K(SYTO9) were approximately 3.7 x 10(5)/M and 1.8 x 10(5)/M. SYTO9 emissions were stronger and overlapped those of PI. Fluorescence resonance energy transfer from SYTO9 to PI was observed. It was, even under normal conditions, possible for DNA bound SYTO9 to have a component in the red region equal to that of DNA bound PI. Potentially confusing emissions were also found to occur when PI was not in sufficient excess to saturate nucleic acid (>0.4 M PI to 1 M DNA base pairs).
Conclusions:
The mechanism is a combination of displacement of SYTO9 by PI and quenching of SYTO9 emissions by fluorescence resonance energy transfer. Confusing results can occur if the relative intensities of the stains or the concentration of PI relative to nucleic acid are not properly accounted for.
Related Concept Videos
Special Staining Techniques
Simple Staining Technique
Fixation and Sectioning
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...
Differential Staining Technique
Labeling DNA Probes
Radioisotopes, fluorophores, or small molecule binding partners like biotin or digoxigenin, are the most widely used reporter tags for labeling DNA probes. These labels can be attached to the probe DNA molecule via...
Immunofluorescence Microscopy
The...