Related Experiment Video
Updated: Aug 22, 2026

Biomechanical Characterization of Human Soft Tissues Using Indentation and Tensile Testing
Published on: December 13, 2016
Uniaxial stress-relaxation and stress-strain responses of human amnion
Michelle L Oyen1, Steven E Calvin, Robert F Cook
1Department of Biophysical Sciences and Medical Physics, University of Minnesota, Minneapolis, MN 55455, USA.
Abstract:
The mechanical behavior of human amnion is examined under uniaxial tensile loading conditions. Monotonic strain-to-failure and stress-relaxation tests are described for membrane strip samples of amnion obtained by removing the chorion cell layer from specimens of whole chorioamnion. The monotonic behavior of the amnion is characterized by a large stress-free strain (approximately 10%) prior to a quadratic load-displacement response. Substantial stress relaxation behavior (ranging from 20-80%) is observed, described by a two time-constant exponential decay. The effects of the application of a topical antiseptic and of prior straining and relaxation on subsequent monotonic failure properties are examined. The results suggest that while amnion is a remarkably resilient tissue material, its mechanical behavior is typical of nonlinear viscoelastic materials, and depends strongly on its history.
Related Concept Videos
Plastic Behavior
Relation between Poisson's ratio, Modulus of Elasticity and Modulus of Rigidity
Residual Stresses in Bending
Generalized Hooke's Law
Normal Strain under Axial Loading
Stress-Strain Diagram - Ductile Materials