Fluorescent sodium ion indicators based on the 1,7-diaza-15-crown-5 system

Vladimir V Martin1, Anca Rothe, Zhenjun Diwu

  • 1Molecular Probes, Inc., 29851 Willow Creek Road, Eugene, OR 97402, USA.

Related Concept Videos

Photoluminescence: Applications01:14

Photoluminescence: Applications

Photoluminescence offers a wide range of applications due to its inherent sensitivity and selectivity. This technique allows for both direct and indirect analyses of the analyte. Direct quantitative analysis is possible when the analyte exhibits a favorable quantum yield for fluorescence or phosphorescence. However, an indirect analysis may be feasible if the analyte is not fluorescent or phosphorescent, or if the quantum yield is unfavorable. Indirect methods include reacting the analyte with...
Aryldiazonium Salts to Azo Dyes: Diazo Coupling01:11

Aryldiazonium Salts to Azo Dyes: Diazo Coupling

The reaction of weakly electrophilic aryldiazonium (also called arenediazonium) salts with highly activated aromatic compounds leads to the formation of products with an —N=N— link, called an azo linkage. This reaction, presented in Figure 1, is known as diazo coupling and occurs without the loss of the nitrogen atoms of the aryldiazonium salt. Highly activated aromatic compounds such as phenols or arylamines favor the diazo coupling reaction. The coupling generally occurs at the para position.
Fluorescence and Phosphorescence: Instrumentation01:25

Fluorescence and Phosphorescence: Instrumentation

Fluorometers and spectrofluorometers are two types of instruments used for measuring molecular fluorescence. These instruments differ in how they select excitation and emission wavelengths and the type of light sources they utilize. Fluorometers use absorption interference filters to choose excitation and emission wavelengths. The excitation source in a fluorometer is typically a low-pressure mercury vapor lamp that emits intense lines distributed throughout the ultraviolet and visible regions.
Flame Photometry: Lab01:16

Flame Photometry: Lab

In a flame photometer, when a solution like potassium chloride is aspirated into the flame, the solvent evaporates, leaving behind dehydrated salt. This salt dissociates into free gaseous atoms in their ground state. Some of these atoms absorb energy from the flame, leading to their excitation. The excited atoms return to the ground state, emitting photons at characteristic wavelengths. Because only electronic transitions are involved, the resulting emission lines are very narrow. The intensity...