Related Experiment Video
Updated: Aug 21, 2026

Murine Endoscopy for In Vivo Multimodal Imaging of Carcinogenesis and Assessment of Intestinal Wound Healing and Inflammation
Published on: August 26, 2014
Small-bowel diseases: prospective evaluation of multi-detector row helical CT enteroclysis in 107 consecutive
Mourad Boudiaf1, Ameer Jaff, Philippe Soyer
1Departments of Body and Vascular Imaging and Gastroenterology, Hôpital Lariboisière-AP-HP, 2 rue Ambroise Paré, 75475 Paris cedex 10, France. mourad.boudiaf@lrb.ap-hop-paris.fr.
Purpose:
To prospectively evaluate multi-detector row helical computed tomographic (CT) enteroclysis for the depiction of small-bowel diseases.
Materials And Methods:
The study group included 107 patients who were suspected of having small-bowel tumor (n = 8), active inflammatory small-bowel disease (n = 18), unexplained gastrointestinal bleeding (n = 36), refractory celiac sprue (n = 14), and low-grade small-bowel obstruction (n = 31). A nasoenteric tube was positioned into the duodenojejunal junction by using fluoroscopic guidance and water was infused with a pressure-controlled pump. After intravenous administration of 120 mL of iodinated contrast material, multi-detector row helical CT enteroclysis images were obtained with 4 x 2.5 mm collimation (four detector rows and 2.5-mm section thickness). Multi-detector row helical CT enteroclysis findings were analyzed by two readers working in consensus. Findings were compared with the results of endoscopy, enteroscopy, videocapsule endoscopy, histopathologic analysis, or clinical follow-up.
Results:
Multi-detector row helical CT enteroclysis was well tolerated in 106 patients; one patient complained of abdominal pain after the examination. Multi-detector row helical CT enteroclysis allowed the diagnosis of small-bowel masses (n = 21), active Crohn disease (n = 9), small-bowel tuberculosis (n = 2), small-bowel lymphoma complicating celiac disease (n = 4), and confirmed low-grade small-bowel obstruction (n = 12). Multi-detector row helical CT enteroclysis demonstrated normal findings in 60 patients. Sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of multi-detector row helical CT enteroclysis were 100%, 95%, 97%, 94%, and 100%, respectively.
Conclusion:
Multi-detector row helical CT enteroclysis allows depiction of small-bowel diseases in patients suspected of having small-bowel conditions.
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and solid...
Endoscopic Procedures II: Colonoscopy
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Endoscopic Procedures III: Video Capsule Endoscopy
Endoscopic Procedures V: ERCP
Patient...
Lower GI Series: Barium Enema
Procedure Details
The examination begins by inserting a lubricated rectal tube into the patient's rectum to administer a radiopaque barium solution. The barium flow is carefully...