Functional relationships of landfill and landraise capacity with design and operation parameters

Vassilis Aivaliotis1, Ioannis Dokas, Maria Hatzigiannakou

  • 1Department of Civil Engineering, Democritus University of Thrace, Xanthi, Thrace, Greece.

Related Concept Videos

Design Example: Analyzing Capacity Contours for Flood Risk Assessment01:17

Design Example: Analyzing Capacity Contours for Flood Risk Assessment

Flood risk assessment involves careful planning and analysis to ensure the safety of communities near water retention structures. Capacity contours are a vital tool in this process, as they illustrate the potential spread of water at specific levels in a given area. In the context of building a bund across a small valley, these contours play a critical role in evaluating the safety of nearby residential areas.In this example, the bund is intended to store stormwater in the valley. The engineers...
Lagrange Multipliers: Problem Solving01:30

Lagrange Multipliers: Problem Solving

A silo with a cylindrical base, flat bottom, and hemispherical roof is a common design in agricultural and industrial storage due to its structural efficiency and ease of construction. Optimizing its dimensions to maximize storage capacity for a given amount of material—i.e., a fixed surface area—is a classic problem in applied calculus and engineering design. The key parameters are the radius r of the base and the height h of the cylindrical section.The total volume of the silo is obtained by...
Design Example: Aggregate Gradation01:24

Design Example: Aggregate Gradation

The right type and quality of aggregates are crucial for concrete as they significantly influence its properties, mix proportions, and cost-effectiveness. If different sources are available for sand, the commonly used fine aggregate in concrete, the selection of sand is primarily based on its gradation.
The grading, or particle-size distribution, of sand is determined using sieve analysis, with standard sizes ranging from 150 μm to 10 mm (ASTM No. 100 sieve to 3⁄8 in. sieve). Sand is sampled...
Design Example: Managing Concrete Workability01:14

Design Example: Managing Concrete Workability

This example deals with managing the workability of concrete for a raft foundation project under hot weather conditions. Workability is crucial for ensuring the concrete is easy to place, compact, and finish. In this scenario, a slump test — a common method to measure the workability of fresh concrete — initially indicated low workability. This was attributed to the rapid water loss from the concrete mix, exacerbated by the high temperatures causing the course aggregates to heat up.
To address...
Design Example: Maintaining Level of an Embankment01:19

Design Example: Maintaining Level of an Embankment

Constructing a roadway embankment over uneven terrain requires precise leveling to ensure stability and proper drainage. Surveyors use a leveling instrument and staff to calculate ground elevations and determine the required fill material at each point along the embankment alignment.The process begins by positioning a leveling instrument near a benchmark with a known elevation. A backsight reading establishes the instrument height, which serves as a reference for subsequent measurements. A...
Bioreactor Design and Operational System01:29

Bioreactor Design and Operational System

Bioreactors are engineered vessels designed to cultivate microorganisms under controlled conditions for industrial bioprocessing. They maintain sterility and allow precise regulation of pH, temperature, oxygen, and nutrient levels to optimize microbial growth and metabolite production. Bioreactors range from small laboratory units of 1 liter to industrial systems holding up to 500,000 liters, though only about 75% of their volume is actively used for fermentation. The remaining headspace...