Objectives:
We sought to identify tube angulations in invasive cardiology, which promise minimal radiation exposure to patients and operators.
Background:
Radiation exposure in invasive cardiology is high.
Methods:
We mapped the fluoroscopic dose-area product per second (DAP/s), applied to an anthropomorphic Alderson-Rando phantom and, in absence of radiation protection devices, the mean personal dose in the operator's position in 10 degrees steps from the 100 degrees right anterior oblique (RAO) to the 100 degrees left anterior oblique (LAO) projection, as well as for all geometrically feasible craniocaudal tube angulations.
Results:
For our specific setting conditions RAO 20 degrees /0 degrees tube angulation generated the lowest DAP/s and operator's personal dose. The mean patient DAP/s and operator personal dose for all postero-anterior (PA) projections, cranialized and caudalized together, rose significantly: 3.7 and 10.6 times the PA 0 degrees baseline values toward LAO 100 degrees and 3.7 and 2.4 times toward RAO 100 degrees , respectively. Patient and operator values for all PA projections, angulated to the right and left, increased approximately 2.5 times toward 30 degrees craniocaudal angulations. Caudal PA 0 degrees /30 degrees - angulation instead of caudal LAO 60 degrees /20 degrees - angulation for the left coronary main stem and cranial PA 0 degrees /30 degrees + view in place of cranial LAO 60 degrees /20 degrees + view for the left anterior descending coronary artery bifurcation enable 2.6-fold dose reductions to the patient and eight- and five-fold dose reductions to the operator, respectively.
Conclusions:
The PA views and RAO views >or=40 degrees , heretofore unconventional in clinical routine, should be favored over steep LAO projections >or=40 degrees whenever possible. Tube angulations that are radiation intensive to the patient exponentially increase the operator's radiation risk.
More Related Videos
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
Related Concept Videos
Cardiac Catheterization I: Pre-Procedure Overview
Cardiac Catheterization III: Left Heart Catheterization
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Cardiac Catheterization II: Right Heart Catheterization