Analysis of the degree of conversion of LED and halogen lights using micro-Raman spectroscopy
M S Soh1, Adrian U J Yap, T Yu
1Department of Restorative Dentistry, Faculty of Dentistry, National University of Singapore, Republic of Singapore.
Abstract:
This study determined the degree of conversion of two LED (light-emitting diodes) (Elipar FreeLight [FL], 3M ESPE; GC e-Light [EL], GC), a high intensity (Elipar TriLight [TL], 3M ESPE) and a very high intensity (Astralis 10 [AS], Ivoclar Vivadent) halogen light. The degree of conversion of these lights was compared to a conventional halogen light (Max [MX] (control), Dentsply-Caulk). Ten different light curing regimens, including pulse (EL1), continuous (FL1, EL2, TL1), turbo (EL3, AS1) and soft-start (FL2, EL4, TL2) modes of various lights were also investigated. Composite specimens of dimensions 3 x 3 x 2 mm were cured with the 10 different light curing regimens investigated. Micro-Raman spectroscopy was used to determine the degree of conversion at the top and bottom surfaces of a composite restorative (Z100, [3M ESPE]) at 60 minutes post-light polymerization. Five specimens were made for each cure mode. The results were analyzed using ANOVA/Scheffe's post-hoc test and Independent Samples t-tests at significance level 0.05. The degree of conversion ranged from 55.98 +/- 2.50 to 59.00 +/- 2.76% for the top surface and 51.90 +/- 3.36 to 57.28 +/- 1.56% for the bottom surface. No significant difference in degree of conversion was observed for the 10 light curing regimens when compared to MX (control). The curing efficiency of LED lights was comparable to halogen lights regardless of curing modes.
More Related Videos
10:42In Depth Analyses of LEDs by a Combination of X-ray Computed Tomography (CT) and Light Microscopy (LM) Correlated with Scanning Electron Microscopy (SEM)
Published on: June 16, 2016
15:04Rejection of Fluorescence Background in Resonance and Spontaneous Raman Microspectroscopy
Published on: May 18, 2011
Related Concept Videos
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and the...
UV–Vis Spectrometers
Flame Photometry: Lab