Related Experiment Video
Updated: Aug 21, 2026

Introduction to Solid Supported Membrane Based Electrophysiology
Published on: May 11, 2013
Solid support membranes for ion channel arrays and sensors: application to rapid screening of pharmacological
Nobunaka Matsuno1, Michael Murawsky, James Ridgeway
1Department of Chemistry, University of Cincinnati, Cincinnati, OH 45221-0172, USA.
Abstract:
The use of solid supported membranes (SSM) was investigated for reconstitution of ion channels and for potential application to screen pharmacological reagents affecting ion channel function. The voltage-gated Kv1.5 K+ channel was reconstituted on an SSM and a current was measured. This current was dependent on the presence of K+, but not Na+, indicating that the Kv1.5 K+ channel maintained cation specificity when reconstituted on SSM. Two pharmacological reagents applied to Kv1.5 K+ channels reconstituted on SSM had similar inhibitory effects as those measured using Kv1.5 in biological membranes. SSM-mounted ion channels were stable enough to be washed with buffer solution and reused many times, allowing solution exchange essential for pharmacological drug screening.
Related Concept Videos
Patch Clamp
In this method, a glass micropipette containing electrolyte solution is tightly sealed against a small portion of the cell membrane. As a result, a patch of the cell...
Potentiometry: Membrane Electrodes