Gustavo Saposnik1, Graciela Rizzo, Adriana Vega
1Department of Organ and Tissue Procurement for transplantation, Garrahan Hospital, Buenos Aires University, Buenos Aires, Argentina. gsaposnik@yahoo.com
Background:
Brain death is the absence of all cortical functions, including the brainstem. The apnea test (AT) is a necessary requisite to complete this diagnosis. Anecdotal reports describing hypotension and acidosis due to apnea test have been reported. However, there are few studies that evaluate complications or difficulties related to this procedure.
Objective:
To analyze medical problems associated with the apnea test.
Methods And Patients:
We analyzed clinical features, potential risk conditions, and problems in 129 brain dead patients during the apnea test. The diagnosis of brain death was made according to the American Academy of Neurology recommendations.
Results:
Clinical problems during the apnea test were detected in more than two thirds of patients, including: arterial hypotension (12%), acidosis (68%), and hypoxemia (23%). Four patients developed major complications, including: pneumothorax, cardiac arrest, bradycardia, atrial fibrillation and myocardial infarction.
Conclusion:
The apnea test is not an innocuous procedure. Complications during the AT are more common than reported and limit organ procurement for transplantation. Guidelines for performing the AT should be followed in order to avoid clinical complications.
Related Concept Videos
Sleep Apnea
The condition is more prevalent among...
Physical Assessment of the Respiratory Tract II: Inspection
Chest Configuration
The chest configuration can...
Acute Respiratory Failure-IV
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...
Alterations in Respiration II
In Biot's breathing, the respiratory rate and depth are irregular, alternating between periods of deep gasping and apnea. Common causes include...
Respiratory Volumes and Capacities I