Related Experiment Video
Updated: Aug 21, 2026

Software for Analysis of Heart Rate and Blood Pressure Time-series Data from the Valsalva Maneuver
Published on: June 27, 2025
Effects of systematic errors in blood pressure measurements on the diagnosis of hypertension
Martin J Turner1, A Barry Baker, Peter C Kam
1Department of Anaesthetics, University of Sydney, Royal Prince Alfred Hospital, Sydney, Australia. mjturner@usyd.edu.au
Objective:
To estimate the effects of systematic errors in measurements of blood pressure on the diagnosis of hypertension.
Methods:
We fitted regression curves to distributions of diastolic and systolic BP from recent Canadian and UK surveys and calculated the effect of systematic measurement errors on changes in the numbers of patients who would be classified hypertensive at thresholds of 85, 90 and 95 mmHg diastolic and 140 and 160 mmHg systolic pressure respectively.
Results:
Overestimation of diastolic BP by 5 mmHg increases the number of patients whose diastolic BP exceeds 85, 90 and 95 mmHg by 102, 132 and 166% respectively. Equivalent underestimation causes 57, 62 and 67% respectively of hypertensive patients to be missed. If systematic error in diastolic pressure is limited to +/-1 mmHg the diagnosis errors are between -15 and +23%. Overestimation of systolic BP by 3 and 5 mmHg increases the number classified as hypertensive by 24 and 43% respectively. Equivalent underestimation causes 19 and 30% of patients with systolic hypertension to be missed.
Conclusions:
Small systematic errors in BP measurements may cause large variations in the proportion of patients diagnosed as hypertensive. To limit over- or under-diagnosis of diastolic hypertension to approximately 20%, systematic errors in diastolic BP measurements should be limited to 1 mmHg. An uncertainty of 3 mmHg may be adequate for detecting systolic hypertension.
Related Concept Videos
Errors occurring during blood pressure monitoring
Several factors...
Hypertension III: Clinical Manifestations and Diagnostic Studies
Measurement of Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
Assessment of blood pressure in brachial artery(two-step method)