Optimization of Transesophageal Atrial Pacing to Assess Atrial Fibrillation Susceptibility in Mice
Published on: June 29, 2022
Signal-averaged P wave duration and the dimensions of the atria
Ulrik Dixen1, Christian Joens, Bo V Rasmussen
1Department of Cardiology, University Hospital of Hvidovre, Copenhagen, Denmark. ulrikdixen@mail.dk
Background:
Delay of atrial electrical conduction measured as prolonged signal-averaged P wave duration (SAPWD) could be due to atrial enlargement. Here, we aimed to compare different atrial size parameters obtained from echocardiography with the SAPWD measured with a signal-averaged electrocardiogram (SAECG).
Methods:
In 74 patients scheduled for elective echocardiography, an SAECG was recorded directly after the echocardiogram. We measured the SAPWD and registered clinical characteristics. The correlation between the SAPWD and the left atrial diameter (LAD), left atrial volume (LAV), right atrial volume (RAV), and total atrial volume (TAV) was analyzed by linear regression analyses. The effect of concomitant risk factors on TAV and the SAPWD was examined.
Results:
Linear regression analysis showed that the correlation between the SAPWD and the LAD was significant (R(2)= 0.11, P = 0.03). However, LAV (R(2)= 0.15, P = 0.009), RAV (R(2)= 0.27, P = 0.0003), and TAV (R(2)= 0.37, P < 0.0001) were more strongly correlated to the SAPWD. The TAV and the SAPWD were not significantly associated with coexisting risk factors.
Conclusions:
The SAPWD is significantly correlated to the atrial size; most strongly to the TAV. The size of the right atrium, with the sinus node area, appears to affect the SAPWD.
Related Concept Videos
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
The Cardiac Cycle
The Process
Electrical signals—sent from the sinoatrial (SA) node in the right atrial wall to the atrioventricular (AV) node between the right atrium and right ventricle—cause both atria to simultaneously contract. When the signal reaches the AV node, it pauses for approximately a tenth of a second, allowing the atria to contract and empty blood into the...
Dysrhythmias IV: Characteristics of Bradyarrhythmias
Dysrhythmias III: Characteristics of Dysrhythmias
Cardiac Cycle
During the cardiac cycle, blood flow through the heart is regulated entirely by changing pressure gradients. This sequence of events begins with the heart in a state of total relaxation, known as mid-to-late diastole, during which blood passively flows from...
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage. When...