Related Experiment Video
Updated: Aug 9, 2026

Surfactant Depletion Combined with Injurious Ventilation Results in a Reproducible Model of the Acute Respiratory Distress Syndrome (ARDS)
Published on: April 7, 2021
Changing pattern of ventilator settings in patients without acute lung injury: changes over 11 years in a single
Phunsup Wongsurakiat1, David J Pierson, Gordon D Rubenfeld
1Pulmonary and Critical Care Medicine Division, Harborview Medical Center, University of Washington, Seattle, WA, USA. sipwo@mahidol.ac.th
Study Objectives:
To determine whether the widely accepted concept of using lower tidal volume (Vt) values in patients with ARDS or obstructive lung disease has affected the pattern of ventilator settings in mechanically ventilated patients who do not have one of these conditions.
Design And Patients:
We performed a retrospective chart review of all patients who had experienced out-of-hospital cardiac arrest and had received ventilatory support for > or = 1 day at a university-affiliated county hospital during the years 1990, 1991, 1992, 1995, 1998, 1999, and 2000.
Results:
In 139 such patients, the mean final Vt values used on the first day of mechanical ventilation were 11.7, 12.4, 11.3, 9.6, 9.7, 9.2, and 9.8 mL/kg in those years, respectively. Multivariate analysis revealed that increasing year (beta-coefficient = -0.24; p = 0.001) and the presence of pulmonary edema (beta-coefficient = -1.2; p = 0.001) were independent predictors of the use of lower Vt values. Patients managed with a low Vt (ie, < 10 mL/kg; mean [+/- SD] Vt, 8.4 +/- 1.3 mL/kg) had a significantly higher incidence of atelectasis than the patients who were managed with traditional, larger Vt values (ie, > or = 10 mL/kg; mean Vt, 11.8 +/- 1.5 mL/kg) [61.1% vs 36.7%, respectively; p = 0.02]. Multivariate analysis revealed that the mean Vt used on days 1, 2, and 3 (<10 mL/kg or > or = 10 mL/kg) was the only predictor of the development of atelectasis during the first 3 days of mechanical ventilation (odds ratio, 0.33; p = 0.015). There was no difference in the incidence of pneumonia, the number of days spent receiving mechanical ventilation, Pao(2)/fraction of inspired oxygen ratio, or respiratory system compliance between the low Vt group and the traditional Vt group.
Conclusion:
Currently, physicians at our hospital use lower Vt values than they have in the past. This is associated with the increase in the incidence of atelectasis in the patients who received ventilation using low Vt values.
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Alterations in Respiration II
In Biot's breathing, the respiratory rate and depth are irregular, alternating between periods of deep gasping and apnea. Common causes include...
Mechanical Ventilation I: Indication and Settings
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...