Related Experiment Video
Updated: Aug 21, 2026

Visually Based Characterization of the Incipient Particle Motion in Regular Substrates: From Laminar to Turbulent Conditions
Published on: February 22, 2018
Choice of rotation speed (rpm) for bio-relevant drug dissolution testing using a crescent-shaped spindle
1Therapeutic Products Directorate, Health Products and Food Branch, Banting Research Centre, Tunney's Pasture (A/L 2202C1), Ottawa, Ontario K1A0L2, Canada. saeed_qureshi@hc-sc.gc.ca
Abstract:
Recently a new crescent-shaped spindle has been proposed to address the issues related to poor hydrodynamics of the USP paddle apparatus and its associated artifacts of high variability and lack of bio-relevant results. For improved comparison of drug dissolution characterization, it is highly desirable to conduct testing using common experimental conditions such as spindle rotation speed. A study was conducted in which different products were tested using the crescent-shaped spindle to propose a common rpm speed for improved comparative drug dissolution testing. Conventional- (200 mg) and extended-release (200 and 400 mg) carbamazepine tablets of multiple brands and amoxicillin capsules (250 and 500 mg) were analysed using the crescent- shaped spindle at 25, 50 and/or 75 rpm. Drug release was evaluated for 1.5h for amoxicillin and for 3.0 and 24h for conventional- and extended-release carbamazepine tablets products respectively. The dissolution media used were 0.05 M phosphate buffer for amoxicillin capsules and water containing 0.5% sodium lauryl sulphate for carbamazepine tablet products. All products showed characteristic drug release profiles, reflecting the fast and slow drug release natures of the products tested with complete drug release within expected time durations. Based on an expected maximum drug release criterion of 85% in a reasonable time, at a relatively slow drug release rate and within a dosing interval, a spindle speed of 25 rpm was found to be the most appropriate. Thus, it is concluded that drug products can be analysed using a single spindle type (crescent) with a single rpm (25) which would, not only result in simpler dissolution procedures, but also provide enhanced efficiencies from economical and regulatory aspects.
Related Concept Videos
In Vitro Drug Dissolution: Compendial Testing Models II
In Vitro Drug Dissolution: Compendial Testing Models I
In Vitro Drug Dissolution: Alternative Methods
Factors Affecting Dissolution: Particle Size and Effective Surface Area
Drug Dissolution: Requirements and Profile Comparison

