Are QT measurements on body surface ECG indicative of ventricular refractory patterns?
Frederik Voss1, Ruediger Becker, Alexander Bauer
1Innere Medizin III, Universitätsklinikum Heidelberg, Im Neuenheimer Feld 410, 69120, Heidelberg, Germany. frederik_voss@med.uni-heidelberg.de
Objective:
Increased dispersion (DISP) of refractoriness (ERP) facilitates the induction of malignant ventricular arrhythmias. Accordingly, QT DISP on surface ECG, supposedly reflecting ERP DISP, has been proposed as a noninvasive marker for risk stratification. However, a comparative analysis of local ERPs and QT measurements is not available so far.
Methods And Results:
In 19 healthy dogs, standard 12 lead surface ECGs were recorded to measure QT and RR intervals. Based on these measurements, corrected QT intervals (QTc, Bazett formula) and DISP (maximum difference) of both QT and QTc intervals (QT-DISP and QTc-DISP, respectively) were calculated. Subsequently, 60 custom-made needle electrodes (12 mm long, 4 bipolar electrodes per needle, interelectrode distance 2.5 mm) were inserted into the left (LV) and right ventricle (RV). At each bipole of 14 randomly selected needle electrodes (8 LV, 6 RV) local ERPs were determined (extrastimulus technique, basic cycle length 1000 ms). Interventricular DISP of ERP (LV-RV-DISP) was defined as the difference between the longest and shortest ERP within both ventricles. Respective values were calculated for each ventricle (LV-DISP; RV-DISP). Scatter plots and correlation analysis did not reveal a significant correlation between QT, QTc, QT-DISP, QTc-DISP and any of the ERP measurements or calculations. Although not statistically significant, the closest correlation was found between QTc and mean ERP and between QTc-DISP and LV-RV-DISP.
Conclusion:
QT measurements on surface ECG are poorly correlated with local ERPs. If anything, QT- or QTc-DISP might provide a rough estimate of interventricular, that is, global DISP of ERP. Local or even intraventricular DISP of ERP is definitely not reflected by these QT measurements.
More Related Videos
08:28Methods for ECG Evaluation of Indicators of Cardiac Risk, and Susceptibility to Aconitine-induced Arrhythmias in Rats Following Status Epilepticus
Published on: April 5, 2011
10:17Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System
Published on: April 11, 2025
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage. When...
Cardiac Action Potential
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin to...
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...