Mass spectrometric analytical methods for the determination of endocrine disrupting chemicals (EDCs)
A Stehmann1, R J W Meesters, Horst Fr Schröder
1Institut fuer Siedlungswasserwirtschaft, Aachen University, Templergraben 55, D-52056 Aachen, Germany. stehmann@isa.rwth-aachen.de
Abstract:
This paper describes a method for the determination of endocrine disrupting chemicals (EDCs) in waste water. The method involves a SPE-C18 extraction followed by a SPE-silica gel column clean up and elution of the analytes with a mixture of acetone/pentane (2+1). Thereafter derivatisation of the analytes with heptafluorobutyric acid anhydride (HFBA) and analysis by gas chromatography/mass spectrometry (GC/MS) with positive electron impact ionisation (EI) or negative chemical ionisation (NCI) using methane as reactant gas was performed. The two different ionisation techniques were compared and the negative chemical ionisation technique proved significant lower limits of detection (LODs) and quantitation (LOQs) than positive electron impact ionisation. Recoveries of the analytes in various spiked waste water samples ranged from 75.4 to 96.9%. The concentrations of the EDCs in feed waste water from three different waste water treatment plants (WWTPs) ranged from non-detectable up to a concentration of 10,305 ng/L for 4-NP and in the corresponding effluent samples from non-detectable to 723 ng/L for BPA.
More Related Videos
07:26A Simple Method for Automated Solid Phase Extraction of Water Samples for Immunological Analysis of Small Pollutants
Published on: January 1, 2016
05:47In Silico Modeling Method for Computational Aquatic Toxicology of Endocrine Disruptors: A Software-Based Approach Using QSAR Toolbox
Published on: August 28, 2019
Related Concept Videos
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
High-Performance Liquid Chromatography: Types of Detectors
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...