Evaluation of Cerebral Blood Flow Autoregulation in the Rat Using Laser Doppler Flowmetry
Published on: January 19, 2020
Laser Doppler anemometry distinguishes primary Raynaud phenomenon from VWF syndrome
Sophie Ziegler1, Michael Gschwandtner, Carina Zöch
1Division of Angiology, Clinic for Internal Medicine II, University of Vienna of the Vienna General Hospital, Währinger Gürtel, Vienna, Austria. sophie.ziegler@akh-wien.ac.at
Objectives:
We evaluated two microcirculatory function-tests, the Laser Doppler (LD)-Anemometry and the Laser Doppler Imager (LDI)-Flowmetry in their value to further elucidate functional behavior of the "Vibration-induced white finger syndrome" (VWF) and to distinguish between Raynaud's phenomenon (RP) of idiopathic or vibration origin.
Participants And Methods:
Ninety-four patients, suffering from RP were studied (78 patients with primary RP and 16 patients with VWF). Measurement of blood cell velocity (BCV) before and after provocation was obtained by nailfold capillary microscopy and an included Laser detector ("Anemometry"). Digital blood flux was recorded by LDI-Flowmetry during a standardized cooling and rewarming thermal challenge.
Results:
"Time to peak" of BCV, a measure of maximal reactive hyperemia was longer in VWF in comparison to primary RP (30.37 versus 19.29 sec P < 0.02), respectively.
Conclusion:
Based on the fact, that prolongation of reactive hyperemia, an indicator of impaired endothelium-dependent vasodilation is also frequently found in peripheral arterial occlusive disease, it is hypothesized that VWF is not only a microcirculatory vasospastic disorder, but may also be related to atherosclerosis. Anemometry, in association with an appropriate provocation-test, could represent a useful non-invasive method for objectifying diagnosis of VWF in patients with RP.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...