Related Experiment Video
Updated: Aug 21, 2026

Estimating Bilateral Atrial Function by Cardiovascular Magnetic Resonance Feature Tracking in Patients with Paroxysmal Atrial Fibrillation
Published on: July 20, 2022
Free-breathing radial acquisitions of the heart
Kate McLeish1, Sebastian Kozerke, William R Crum
1Departmento de Ingenieria Electrica, Pontificia Universidad Catolica de Chile, Santiago.
Abstract:
There is considerable interest in performing free-breathing acquisitions of the heart in order to obtain high-quality images without the need for multiple, long breathholds. In this article a 3D motion-correction method is described that is based on image registration of in-plane data and through-plane slice tracking. A number of fast radial undersampled images are acquired, each of which is free of motion artifacts. Initially, in-plane translational and rotational motion between each image was corrected before combining the data to give a fully sampled image. At the next stage, correction of in-plane deformation, in addition to translations and rotations, was performed in the image domain. Through-plane translational motion was compensated using a navigator echo to move the acquisition plane. Using this method, information on the motion of the heart was captured at the same time as acquiring the image data. No motion model, assumptions about the motion, or training data are required. The method is demonstrated on phantom data and cardiac images acquired on free-breathing volunteers.
Related Concept Videos
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of the Cardiovascular System IV: Auscultation
Normal Heart Sounds
S1 (First Heart Sound)-
S1 is made by the closure of the mitral and tricuspid valves (atrioventricular valves), marking the beginning of systole.
S2 (Second Heart Sound)-
S2 is made by the closure of the aortic and pulmonic valves (semilunar valves), marking the end of the systole.
Cardiovascular System Abnormal Findings II: Auscultation
Abnormal Heart Sounds
Gallops:
Respiratory System Abnormal Finding II: Palpation and Auscultation
Palpation Findings
During a respiratory assessment, palpation can reveal several vital abnormalities:
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like asthma or COPD,...