Related Experiment Video
Updated: Aug 21, 2026

Individualized Stem-positioning in Calcar-guided Short-stem Total Hip Arthroplasty
Published on: February 27, 2018
Hip revision using the Exeter stem, impacted morselized allograft bone and cement: a consecutive 5-year
Ewald Ornstein1, Herbert Franzén, Ragnar Johnsson
1Department of Orthopedics, Hässleholm-Kristianstad Hospitals, SE-281 25 Hässleholm, Sweden. ewald.ornstein@skane.se
Background:
Impaction grafting in hip revision surgery is widely used but studies with mid- and long-term follow-up are scarce.
Patients, Methods And Results:
A 5-year radiostereometric (RSA) follow-up of 15 hip revisions with the Exeter stem, morselized impacted allograft bone and cement revealed that 3 stems had not migrated between 2 and 5 years after revision, 11 stems had migrated to a minor degree in at least 1 direction, and 1 stem was loose according to RSA but without any radiographic signs of loosening or pain. The pain score was comparable to primary arthroplasties.
Interpretation:
From a 5-year perspective, first-time hip revisions for aseptic loosening with impacted morselized allograft bone and cement appear to yield good clinical results, although stem migration continues to a minor degree 2 years after revision.