Related Experiment Video
Updated: Aug 21, 2026

Integration of Miniaturized Solid Phase Extraction and LC-MS/MS Detection of 3-Nitrotyrosine in Human Urine for Clinical Applications
Published on: July 14, 2017
Six spectroscopic methods for detection of oxidants in urine: implication in differentiation of normal and
1Division of Forensic Toxicology, Office of Armed Forces Medical Examiner, Armed Forces Institute of Pathology, Rockville, Maryland 20850, USA.
Abstract:
Six separate methods to detect oxidants in urine were developed. The presence of the oxidants was established by initial oxidation of ferrous to ferric ion and detecting the ferric by chromogenic oxidation or complex formation. The reagents for chromogenic oxidation were N,N-dimethylamoino-1,4-phenylenediamine (DMPDA), 2,2'-azino-bis(3-ethylbenzthiazoline-6-sulfonic acid (ABTS), and 2-amino-p-cresol (APC), and the reagents for the chromogenic complex were xylenol orange (XO), 8-hydroxy-7-iodo-5-quinolinesulfonic acid (HIQSA), and 4,5-dihydroxy-1,3-benzene-di-sulfonic acid (HBSA). All methods showed comparable results when tested for ferric, chromate, permanganate, oxychloride, hydrogen peroxide, oxone, tert-butylhydroperoxide, and cumenehydroperoxide at a concentration of 1.0 mmol/L in water (CV < 7%). The nitrite results are comparable only with DMPDA and APC. Periodate responded to the highest oxidation number (ON = 8) by chromogenic oxidation but lowest (ON = 2) by the chromogenic complex. The iodate responded only to the chromogenic oxidation with ON = 6. The linearity of the procedures was established by chromate in water. The linear concentrations were 0.09-12.00 mE/L for DMPDA, ABTS, APC, and HBSA and 0.09-6.00 mE/L for XO and HIQSA. In all methods, the correlation coefficients were > or = 0.9991 and precisions were within +/- 5.6%. The methods were used to test oxidants in 238 urine specimens. The chromate at 3.0 mE/L in water was used as standard. The correlation coefficients of 0.9600-0.9853 and the ANOVA test (F = 0.90, F(critical) = 2.22 at P(0.48)) indicated that the methods correlated well. The median concentration of oxidants in the specimens was 0.21 mE/L with an average and standard deviation of 0.62 +/- 1.19 (range 0.04-8.83 mE/L). When Grubbs' statistical test was applied to the specimen results, no specimen was found to be outlier or could be considered as adulterated. The Grubbs' test also revealed that the threshold concentration to identify urine adulteration was 29 mE/L at confidence level of 99%.
More Related Videos
04:53Detection of Total Reactive Oxygen Species in Adherent Cells by 2',7'-Dichlorodihydrofluorescein Diacetate Staining
Published on: June 23, 2020
08:23Chemiluminescence-based Assays for Detection of Nitric Oxide and its Derivatives from Autoxidation and Nitrosated Compounds
Published on: February 16, 2022
Related Concept Videos
Urine Studies I: Urinalysis
Redox Titration: Other Oxidizing and Reducing Agents
Redox Titration: Overview
Oxidations of Aldehydes and Ketones to Carboxylic Acids
Aldehydes readily undergo oxidation in strong oxidizing agents such as potassium permanganate and chromic acid. The oxidation can also be carried out using mild oxidizing agents such as silver oxide. In fact, aldehydes can be easily oxidized...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...