Related Experiment Video
Updated: Aug 21, 2026

Ultrasound Based Assessment of Coronary Artery Flow and Coronary Flow Reserve Using the Pressure Overload Model in Mice
Published on: April 13, 2015
Determinants of coronary blood flow in humans: quantification by intracoronary Doppler and ultrasound
Heinrich Wieneke1, Clemens von Birgelen, Michael Haude
1Department of Cardiology, University Essen, Hufelandstr. 55, D-45122 Essen, Germany. heinrich.wieneke@uni-essen.de
Insights
Coronary flow is determined by lumen area and blood flow velocity. Lumen size adapts to long-term needs, while flow velocity adjusts to short-term oxygen demands.
Area of Science:
- Cardiovascular Physiology
- Coronary Circulation Dynamics
Background:
- Coronary flow is crucial for myocardial oxygen supply.
- The interplay between lumen area and flow velocity in regulating coronary flow is not fully elucidated.
Purpose of the Study:
- To investigate the mechanisms by which lumen area and coronary flow velocity interact with hemodynamic and morphometric factors.
- To understand how these factors influence overall coronary blood flow.
Main Methods:
- Intracoronary Doppler and ultrasound measurements in 28 patients.
- Assessment of proximal coronary artery lumen cross-sectional area and flow velocity.
- Echocardiography for left ventricular mass; calculation of stress-mass-heart rate and pressure-rate products.
Main Results:
- Global coronary flow significantly increased during adenosine-induced hyperemia (197 to 637 ml/min).
- Global coronary flow correlated with stress-mass-heart rate product (r=0.62).
- Coronary cross-sectional area related to left ventricular mass (r=0.61), while flow velocity related to pressure-rate product (r=0.64). No interaction found between area and velocity.
Conclusions:
- Coronary lumen size and flow velocity are regulated by distinct physiological factors.
- Long-term coronary flow adaptation involves changes in lumen size.
- Short-term myocardial oxygen needs are met by alterations in resting coronary flow velocity.
Abstract:
The direct determinants of coronary flow are lumen area and blood flow velocity; however, the precise mechanisms that control these factors are not fully understood. The aim of the present study was to assess by which mechanisms lumen area and coronary flow velocity interact with hemodynamic and morphometric factors, thereby influencing coronary flow. Intracoronary Doppler and ultrasound measurements were performed in 28 patients without coronary lumen irregularities. Flow velocity and lumen cross-sectional area were measured in the proximal segments of all three coronary arteries. Global lumen cross-sectional area and global flow were obtained by adding up the values of all three coronary arteries. Left ventricular mass was assessed by echocardiography. Stress-mass-heart rate and pressure-rate products reflecting myocardial oxygen demand were calculated. Global coronary flow increased during adenosine-induced hyperemia from 197 +/- 72 to 637 +/- 204 ml/min (P < 0.001). Global coronary flow closely correlated with the stress-mass-heart rate product (r = 0.62; P < 0.001). Looking at the two constituents of flow separately, global coronary cross-sectional area was closely related to left ventricular muscle mass (r = 0.61; P < 0.001), whereas mean coronary flow velocity at rest showed a strong linear relation with the pressure-rate product (r = 0.64; P < 0.001). There was no interaction between cross-sectional area and blood flow velocity in any of the coronary vessels. Coronary lumen size and flow velocity, the two determinants of coronary flow, are principally determined by different physiological factors. Long-term flow adaptation is achieved by an increase in coronary lumen size, whereas short-term myocardial oxygen requirements are met by changes in resting flow velocity.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Acute Coronary Syndrome III: Diagnostic Studies