Intravenous contrast material administration at 16-detector row helical CT coronary angiography: test bolus versus
Filippo Cademartiri1, Koen Nieman, Aad van der Lugt
1Department of Radiology, Erasmus Medical Center, Dr Molenwaterplein 40, 3015 GD Rotterdam, the Netherlands. filippocademartiri@hotmail.com
Purpose:
To compare test bolus and bolus-tracking techniques for intravenous contrast material administration at 16-detector row computed tomographic (CT) coronary angiography.
Materials And Methods:
This study had institutional review board approval, and patients gave informed consent. Thirty-eight patients (mean age, 60 years; three women) were randomized into two groups according to bolus timing technique: group 1 (20-mL test bolus with 100-mL main bolus) and group 2 (bolus tracking with 100-mL main bolus). All patients underwent electrocardiography-gated 16-detector row CT coronary angiography with 12 detectors (collimation, 0.75 mm; rotation time, 420 msec). In group 1, test bolus peak attenuation was used as a delay, while in group 2, a +100-HU threshold in ascending aorta triggered angiographic acquisition, with an additional 4-second delay for patient instruction. Attenuation was measured in the longitudinal direction throughout the examination in three main vessels: ascending aorta (region of interest [ROI] 1), descending aorta (ROI 2), and main pulmonary artery (ROI 3). Mean attenuation and slope of bolus geometry curve were calculated in each patient and ROI. Attenuation at origin of coronary arteries was measured. Student t test was used to compare results.
Results:
Mean scan delay was 6 seconds longer in group 2 (P < .05). Average attenuation values were 306.6 HU +/- 44.0 (standard deviation) and 328.2 HU +/- 58.6 (P > .05) in ROI 1, 291.6 HU +/- 45.1 and 326.4 HU +/- 62.6 (P > .05) in ROI 2, and 354.7 HU +/- 78.0 and 305.3 HU +/- 71.4 (P < .05) in ROI 3 for groups 1 and 2, respectively. Average slope values were 5.8 and -0.8 (P < .05) in ROI 1, 7.7 and 0.7 (P < .05) in ROI 2, and -1.0 and -13.3 (P < .05) in ROI 3 for groups 1 and 2, respectively. Average attenuation values in left main, left anterior descending, and left circumflex arteries were higher in group 2 (P < .05); there were no differences (P > .05) between groups in right coronary artery.
Conclusion:
Bolus-tracking yields more homogeneous enhancement than does the test bolus technique.
More Related Videos
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
08:41Novel In Vivo Micro-Computed Tomography Imaging Techniques for Assessing the Progression of Non-Alcoholic Fatty Liver Disease
Published on: March 24, 2023
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography
Imaging Studies VII: Vascular Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Radiological Investigation I: X-ray and CT
Cardiac Catheterization I: Pre-Procedure Overview