Stable oxygen isotopes from theropod dinosaur tooth enamel: interlaboratory comparison of results and analytical

William H Straight1, Jonathan D Karr, Julia E Cox

  • 1Duke Environmental Stable Isotope Laboratory (DEVIL), Duke University, Department of Biology & Nicholas School of the Environment and Earth Sciences, National Phytotron, Durham, NC 27708-0340, USA. william.straight@duke.edu

Related Concept Videos

Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences01:20

Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences

Inductively coupled plasma–mass spectrometry (ICP–MS) is a highly selective and sensitive technique for accurate elemental analysis. Though the analysis of ICP–MS mass spectra is comparatively straightforward, it is affected by spectroscopic and non-spectroscopic interferences. Spectroscopic interferences arise when the plasma contains ionic species with an m/z value the same as the analyte ion. Spectroscopic interference can be categorized as isobaric, polyatomic ions, and refractory oxide ion...
The Fossil Record02:56

The Fossil Record

The fossil record documents only a small fraction of all organisms that have ever inhabited Earth. Fossilization is a rare process, and most organisms never become fossils. Moreover, the fossil record only exhibits fossils that have been discovered. Nevertheless, sedimentary rock fossils of long-lived, abundant, hard-bodied organisms dominate the fossil record. These fossils offer valuable information, such as an organism's physical form, behavior, and age. Studying the fossil record helps...
Mass Spectrometry: Isotope Effect01:13

Mass Spectrometry: Isotope Effect

Most elements exist in nature as a mixture of isotopes. The isotopes differ in weight due to their respective number of neutrons. The molecular weight of a molecule is different depending on the specific isotope of its elements involved. As a result, the mass spectrum of the molecule exhibits peaks from the same fragment at multiple positions. The positions of these mass signals depend on the mass differences between isotopes. Furthermore, the intensity of these signals is dependent on the...
Atomic Emission Spectroscopy: Interference01:30

Atomic Emission Spectroscopy: Interference

In atomic emission spectroscopy (AES), high-temperature atomizers excite a broad range of elements and molecules that generate complex emissions from sources such as oxides, hydroxides, and flame combustion products in the flame or plasma. Several strategies can be employed to minimize spectral interferences caused by overlapping emission lines or bands. These include increasing instrument resolution, choosing alternative emission lines, optimally placing the detector in low-background regions,...