Related Experiment Video
Updated: Aug 21, 2026

Research and Development of High-performance Explosives
Published on: February 20, 2016
Use of ARC in screening for explosive properties
1Eastman Kodak Company, 1100 Ridgeway Avenue, Rochester, NY 14652-6270, USA. glenn.bodman@kodak.com
Abstract:
The use of a modified version of the accelerating rate calorimeter (ARC) as a screening method for the explosive properties of chemicals has been investigated. Definitive tests for classifying energetic chemicals for transportation are provided by UN Recommendations [United Nations, Recommendations on the Transport of Dangerous Goods, Manual of Tests and Criteria, third revised ed., 1999]. Recently, decomposition energy screening criteria were added to the recommendations, however, maximum rate of pressure rise in a closed vessel may provide a less conservative, more accurate screen. Pressure rate data for organic chemicals are compared to the UN test results. Preliminary screens are suggested to minimize the need for the larger scale, more expensive, and time-consuming UN-recommended testing. Results from this method are compared to those from published mini-autoclave data [M.W. Whitmore, G.P. Baker, J. Loss Prev. Process Ind. 12 (1999) 207-216]. Further work is planned to expand the range of chemical classes tested and to specify acceptable, conservative screening criteria.
Related Concept Videos
Atomic Emission Spectroscopy: Overview
Atomic Emission Spectroscopy: Lab
Atomic Emission Spectroscopy: Instrumentation
Gas Chromatography: Types of Detectors-II
Atomic Absorption Spectroscopy: Atomization Methods
Atomic Fluorescence Spectroscopy