Design and Application of a Fault Detection Method Based on Adaptive Filters and Rotational Speed Estimation for an Electro-Hydrostatic Actuator
Published on: October 28, 2022
Robust motor speed control under time varying loads in moving actuator type artificial heart (AnyHeart)
1Interdisciplinary Program in Medical and Biological Engineering Major, Graduate School Department of Biomedical Engineering, Seoul National University, Seoul, Korea.
Abstract:
The Moving Actuator type artificial heart(AnyHeart) as well as many other artificial hearts uses a motor as its power source. For controllability of control parameters such as pump rate, pump output, blood pressure profile and flow form, the precise motor speed control is important. However, because the implantable device has limited carrying capacity of hardware components in size and number, applying diverse motor control methods are not possible. In addition, the existing PI (Proportional-Integral) motor controller does not show satisfactory performance. A new controller that is sufficiently robust for the changes of load and physical system parameters has been designed and tested. The robust speed controller is based on the sliding mode control method that is applicable to a system of which the ranges of uncertainty in physical parameters are known. In a mock circulation system test, the actual speed showed good tracking characteristics in respect to the reference speed. Fast follow-up characteristics were also observed under high afterload and speed conditions. The speed error, current and power consumption were reduced by about 40%. The proposed control technique overcomes the limitations of the PI controller, and makes important improvements in both performance and stability.
Related Concept Videos
Time-Domain Interpretation of PD Control
Consider the example of control of motor torque. Initially, a positive...
Node Analysis for AC Circuits
To unravel the complexities of this system, nodal analysis is employed, a powerful technique founded on Kirchhoff's current law (KCL), which remains valid for phasors. AC circuits can effectively be...
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
Electro-mechanical Systems
A key component of the DC motor is the armature, a rotating circuit positioned within a magnetic field. As an electric current passes through the...
Pathophysiology of Cardiac Performance
Torque On A Current Loop In A Magnetic Field
Consider a rectangular current-carrying loop containing N turns of wire, placed in a uniform magnetic field. The net force on a current-carrying loop...