Related Experiment Video
Updated: Jun 30, 2026

A Method of Nodose Ganglia Injection in Sprague-Dawley Rat
Published on: November 25, 2014
A modified needle-inside-needle technique for the ganglion impar block
Muhammad A Munir1, Junming Zhang, Mahmood Ahmad
1Department of Anesthesiology, Perioperative and Pain Medicine, Brigham and Women's Hospital, Harvard Medical School, 75 Francis Street, Boston, Massachusetts, USA. mmunir@partners.org
Purpose:
The ganglion impar is the fused terminus of the paired sympathetic chain located at the level of the sacrococcygeal junction. It has been blocked using a bent and a curved spinal needle via the anococcygeal ligament. It has also been approached through the sacrococcygeal disc using a straight spinal needle. We describe a needle-inside-needle modification of the latter approach.Technical features: A 22-gauge (G), 1(1/2)-inch (38 mm) needle is introduced through the sacrococcygeal ligament under fluoroscopy via the sacrococcygeal disc. A 25-G, 2-inch (50 mm) needle is introduced through the 22-G needle. Placement is confirmed with injection of iopamidol 300, 0.2 mL in the retroperitoneal space with the comma sign.
Conclusions:
The bent and curved needle techniques are associated with significant discomfort, tissue trauma and risk of rectal perforation due to difficulty in obtaining a midline needle tip position. The straight spinal needle approach minimizes these problems, however there is increased risk of discitis and a longer spinal needle may help also raise incidence of needle breakage. The needle-inside-needle technique may reduce these risks.
More Related Videos
Related Concept Videos
Drugs Acting on Autonomic Ganglia: Blockers
Local Anesthetics: Clinical Application as Intravenous Regional Anesthesia
One of the advantages of...