Identification and quantification of N(epsilon)-(Hexanoyl)lysine in human urine by liquid chromatography/tandem mass
Yoji Kato1, Akihiro Yoshida, Michitaka Naito
1School of Human Science and Environment, University of Hyogo, Himeji 670-0092, Japan. yojikato@shse.u-hyogo.ac.jp
Abstract:
The identification and quantification of N(epsilon)-(hexanoyl)lysine (N(epsilon)-HEL), which was found from the reactions between lipid hydroperoxide and lysine, from human urine was examined using liquid chromatography/tandem mass spectrometry (LC/MS/MS). The N(epsilon)-HEL in the partially purified urine fraction was identified using LC/MS/MS by several approaches including precursor/product ion scans. The peak found by the multiple-reaction monitoring (MRM) of the collision-induced fragmentation of N(epsilon)-HEL was clearly observed in urine, and the elution position coincided with the synthetic standard N(epsilon)-HEL. The product, estimated N(epsilon)-HEL, was absorbed by a specific antibody to N(epsilon)-HEL. Moreover, N(alpha)-HEL, one of the plausible hexanoyl adducts from the reaction between the N(alpha) moiety of L-lysine and the peroxidized lipid, was hardly detected in urine samples, suggesting that the origin of the N(epsilon)-HEL is the peroxidized lipid-modified proteins but not artificial hexanoylated L-lysine. Using the MRM technique, the amount of urinary N(epsilon)-HEL from the control subjects (observed healthy) was estimated to be 1.58 +/- 0.23 mumol/mol of creatinine. A comparative study of the urinary N(epsilon)-HEL with an oxidative stress marker, 8-oxo-7,8-dihydro-2'-deoxyguanosine, showed a high correlation (r = 0.844) between the two biomarkers. Furthermore, the quantification of N(epsilon)-HEL in the control and diabetic urines revealed that the urinary N(epsilon)-HEL from diabetic subjects (3.21 +/- 0.65 mumol/mol of creatinine) was significantly higher than that from the control subjects.
More Related Videos
08:41Integration of Miniaturized Solid Phase Extraction and LC-MS/MS Detection of 3-Nitrotyrosine in Human Urine for Clinical Applications
Published on: July 14, 2017
08:37Sampling Human Indigenous Saliva Peptidome Using a Lollipop-Like Ultrafiltration Probe: Simplify and Enhance Peptide Detection for Clinical Mass Spectrometry
Published on: August 7, 2012