Related Experiment Video
Updated: Aug 17, 2026

Fluorescence detection methods for microfluidic droplet platforms
Published on: December 10, 2011
Adaptation of an evaporative light-scattering detector to micro and capillary liquid chromatography and response
Karen Gaudin1, Arlette Baillet, Pierre Chaminade
1Groupe de Chimie Analytique de Paris-Sud: EA 3343, Laboratoire de Chimie Analytique, Faculté de Pharmacie, Châtenay-Malabry, France.
Abstract:
A commercially available evaporative light-scattering detection (ELSD) system was adapted for micro and capillary LC. Therefore the various parameters involved in the droplet formation during the nebulization step in the ELSD system were studied. It was shown that the velocity term in the Nukiyama Tanasawa equation remains constant, leading to droplets of the same order of magnitude for narrow bore and capillary columns. Consequently, the ELSD modification was performed by decreasing the internal diameter of the effluent capillary tube in the nebulizer nozzle and by keeping its external diameter constant. Next, response curves for a conventional and the developed micro and capillary LC were compared as to investigate why a linear ELSD response is often obtained when used in micro or capillary LC. By splitting the flow rate post column, we showed that the nebulization process was not at the origin of the phenomenon. For ceramide III and tripalmitin, the response curves were found to be non-linear. However the curvature was less significant when the columns internal diameter decreased. Calculated particle size profiles for micro or capillary LC suggest that the particle entering the detection chamber are bigger than under conventional LC conditions. Last, triethylamine and formic acid were used to increase the response of the detector. The response enhancement, expected from previous studies, was established for the two lipids involved in this study.
More Related Videos
Related Concept Videos
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Types of Detectors-II
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Instrumentation
High-Performance Liquid Chromatography: Types of Detectors

