Simultaneous determination of dysprosium and iron in urine by capillary zone electrophoresis coupled to cloud point
Claudia Ortega1, Soledad Cerutti, Roberto A Olsina
1Area de Química Analítica, Universidad Nacional de San Luis, Chacabuco y Pedernera, San Luis 5700, Argentina.
Abstract:
Automated preconcentration strategies are needed when analyzing metals in real samples by capillary electrophoresis (CE) with UV detection. The on-line incorporation of cloud point extraction (CPE) to flow injection analysis (FIA) associated with CE for simultaneously determining dysprosium and iron at ppb levels in urine is presented and evaluated for the first time. The preconcentration step is mediated by micelles of the non-ionic surfactant polyethyleneglycol-mono-p-nonylphenylether (PONPE 7.5) with 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol. The micellar system containing the complex was loaded into the FIA manifold at a flow rate of 8 mlmin(-1), and the surfactant rich-phase was retained in a microcolumn packed with cotton, at pH 9.2. The surfactant-rich phase was eluted with 50 microl acetonitrile directly into the CE sample vial, allowing to reach an enrichment factor of 200-fold for a 10 ml sample urine. The type and composition of the background electrolytes (BGE) were investigated with respect to separation selectivity, reproducibility and stability. A BGE of 20mM sodium tetraborate buffer containing 13% acetonitrile, pH 9.0 was found to be optimal for the separation of metal chelates. Detection was performed at 585 nm. An enhancement factor of 200 was obtained for the preconcentration of 10 ml of sample solution. The detection limits for the preconcentration of 10 ml of urine were 0.20 microgl(-1) for Dy, and. 0.48 microgl(-1) for Fe. The calibration graphs using the preconcentration system were linear with a correlation coefficient of 0.9989 (Dy) and 0.9976 (Fe) at levels near the detection limits up to at least 500 microgl(-1). The method was successfully applied to the determination of dysprosium and iron in urine for monitoring the elimination of dysprosium-based pharmaceuticals.
More Related Videos
09:51TD-DFT Guided Advanced E-Eye Sensing Technique for On-site Quantification of Fe, Cr, F, and As in the Environmental, Biological, and Food Samples
Published on: September 19, 2025
09:42Fabrication of a Dipole-assisted Solid Phase Extraction Microchip for Trace Metal Analysis in Water Samples
Published on: August 7, 2016
Related Concept Videos
Precipitation and Co-precipitation
Extraction: Advanced Methods
Ion-Exchange Chromatography
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Electrodeposition
Electrodeposition can...