Self-measured home blood pressure in predicting ambulatory hypertension
George A Mansoor1, William B White
1Section of Hypertension and Clinical Pharmacology, University of Connecticut Health Center, Farmington, Connecticut, USA. Mansoor@NSO1.uchc.edu
Background:
Physicians are commonly uncertain whether a person with office blood pressure (BP) around 140/90 mm Hg actually has hypertension. This is primarily because of BP variability. One approach is to perform self-measured home BP and determine if home BP is elevated. There is a general agreement that if home BP is >/=135/85 mm Hg, then antihypertensive therapy may be commenced. However, some persons with home BP below this cut-off will have ambulatory hypertension. We therefore prospectively study the role of home BP in predicting ambulatory hypertension in persons with stage 1 and borderline hypertension.
Methods:
We studied in a cross-sectional way home and ambulatory BP in a group of 48 patients with at least two elevated office BP readings. The group was free of antihypertensive drug therapy for at least 4 weeks and performed 7 days of standardized self-BP measurements at home. We examined the relationships of the three BP methods and also defined a threshold (using receiver operating curves) for home BP that captures 80% of ambulatory hypertensives (awake BP >/=135/85 mm Hg).
Results:
Office systolic BP (145 +/- 13 mm Hg) was significantly higher than awake (139 +/- 12 mm Hg, P = .013) and home (132 +/- 11 mm Hg, P < .001) BP. Office diastolic BP (88 +/- 4 mm Hg) was higher than home diastolic BP (80 +/- 8 mm Hg, P < .001) but not different from awake diastolic BP (88 +/- 8 mm Hg, P = .10). Home BP had a higher correlation (compared with office BP) with ambulatory BP. The home BP-based white coat effect correlated with ambulatory BP-based white coat effect (r = 0.83, P = .001 for systolic BP; r = 0.68, P = .001 for diastolic BP). The threshold for home BP of 80% sensitivity in capturing ambulatory hypertension was 125/76 mm Hg.
Conclusions:
Our preliminary data suggest that a lower self-monitored home BP threshold should be used (to exclude ambulatory hypertension) in patients with borderline office hypertension.
Related Concept Videos
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pre-Procedural Guidelines for Assessing Blood Pressure
Hypertension III: Clinical Manifestations and Diagnostic Studies
Errors occurring during blood pressure monitoring
Several factors...
Assessment of blood pressure in brachial artery(two-step method)
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement