Related Experiment Video
Updated: Aug 21, 2026

Optocardiography and Electrophysiology Studies of Ex Vivo Langendorff-perfused Hearts
Published on: November 7, 2019
Does cardiac pacing reproduce the mechanism of focal impulse initiation?
Emilio Macchi1, Silvana Baruffi, Stefano Rossi
1Dipartimento di Biologia Evolutiva e Funzionale, Sezione Fisiologia, Italy. macchi@biol.unipr.it
Abstract:
Stimulation of myocardium by either a native pacemaker or an artificial stimulus requires the initiation of a self-propagating wave of depolarization originating from the site of initial activation. In the present study we perform artificial stimulation at a site of focal discharge with the aim to compare the two mechanisms of impulse formation. High resolution epicardial mapping in senescent rat hearts provided examples of focal discharge during sinus rhythm at a single epicardial breakthrough (BKT) point emerging from an isolated Purkinje-ventricular muscle junction (PMJ) site. Stimulation was also performed at the same BKT point and potential distributions recorded during spontaneous and artificial stimulation were compared. During excitation latency, the negative potential pattern was elongated perpendicularly to fiber direction at both pacing and BKT point, in agreement with virtual cathode membrane polarization predicted by the bidomain model during point stimulation. During impulse initiation, activation wave fronts were initially circular around pacing site or BKT point and then elongated along local fiber direction. The similarity between impulse initiation during focal discharge and point stimulation in cardiac muscle suggests that high resolution pace mapping studies can help to elucidate the mechanism of abnormal impulse formation.
Related Concept Videos
Electrophysiology of Normal Cardiac Rhythm
Cardiac Action Potential
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
Conduction System of the Heart
This system relies on the unique properties of nodal and Purkinje cells:...
Mechanism of Cardiac Arrhythmias
Specialized Characteristics of Cardiac Muscles
Cardiac muscle cells are smaller than skeletal muscles, averaging 10–20 mm in diameter and 50–100 mm in length. However, they have large energy demands for continuous contraction and relaxation. This energy is almost exclusively derived from aerobic metabolism of energy reserves in...

