Purpose:
Polyethylene glycol (PEG) based hydrogel is available as a tissue sealant and hemostatic aid. We determined the long-term safety and efficacy of its use as a tissue sealant for laparoscopic partial nephrectomy in a porcine model.
Materials And Methods:
A total of 16 swine were cycled to 1 control group and 3 treatment groups, which underwent laparoscopic partial nephrectomy with hemostasis achieved only with application of a biodegradable PEG based hydrogel. The 3 treatment groups were sacrificed at 2, 6 and 12 weeks, respectively. Humoral immune response to the hydrogel used in the porcine abdomen was examined using enzyme-linked immunosorbent assay to detect antibodies in the serum at 0, 2, 6 and 12 weeks. Cell mediated immune response was examined using a lymphocyte proliferation assay to measure the response of leukocytes to various mitogens and antigens, including the polymerized hydrogel, at the same intervals.
Results:
Hemostasis was satisfactory after hydrogel application. No adverse effects in the immediate and delayed periods were noted. At 2, 6 and 12 weeks there were no significant differences in hemoglobin or creatinine levels, or in the humoral immune response by enzyme-linked immunosorbent assay. There was no significant difference between test and control pig reactivity to hydrogel as an antigen in the lymphocyte proliferation assay at any time point. Histologically by 6 weeks the animals had almost absorbed the hydrogel with acute inflammation and foreign body reaction resolving by 6 to 12 weeks. No deleterious effect to renal tubules was seen.
Conclusions:
Biodegradable PEG based hydrogel is effective for long-term use as an agent for hemostasis. There was no detectable humoral immune response and no cell mediated immune response to sealant after 2 weeks. This represents promising sealant technology and it should be further investigated for human use.