Background:
Endoscopic vessel harvest is viewed as a safe, reliable, and cost-effective method for greater saphenous vein removal. As the radial artery has more recently become a popular conduit choice in coronary artery revascularization, we describe herein an endoscopic technique for radial artery harvest in our first 50 patients as an alternative to the more traditional open technique.
Methods:
From November 2001 to July 2002, 54 radial arteries were harvested endoscopically in 50 patients utilizing the VasoView Endoscopic Vessel Harvesting System, an Esmark bandage, and a pneumatic cuff tourniquet.
Results:
No patients experienced symptoms of vascular compromise, or signs of infection in the donor arm. No adjunctive procedures were required during the vessel harvest, i.e., conversion to open technique. All radial arteries were successfully removed with endoscopic technique and 53 of the 54 radial arteries were successfully used as bypass conduits. Although the quality of the radial artery harvested remains subjective, we found less vasospasm than in our experience with the open technique. Thirty-day follow-up revealed no readmissions, no cardiac ischemic complications, no significant complications with the donor arm, and an excellent cosmetic result.
Conclusions:
Endoscopic harvest of the radial artery with the tourniquet technique may offer advantages over the more traditional open technique.
Related Concept Videos
Local Anesthetics: Clinical Application as Intravenous Regional Anesthesia
One of the advantages of...
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation