Experimental design as a tool when evaluating stationary phases for the capillary electrochromatographic separation
Helena Brunnkvist1, Bo Karlberg, Linda Gunnarsson
1Department of Analytical Chemistry, Stockholm University, SE-10691 Stockholm, Sweden.
Abstract:
Two different capillary electrochromatography (CEC) stationary phases, Hypersil phenyl and Hypersil C(18), have been characterised with respect to their ability to separate the four basic peptides H-Tyr-(D)Ala-Phe-Phe-NH(2) (TAPP), H-Tyr-(D)Ala-Phe-NH(2) (TAP), H-Phe-Phe-NH(2) (PP) and H-Phe-NH(2) (P). Optimal separation conditions were first established separately for the two phases by applying experimental design in a stepwise procedure. The first step comprised a study to acquire basic knowledge about the variables, their influence on the response and their respective experimental domains for each of the two stationary phases. The second step was screening the significant variables and the third step was an optimisation with response surface modelling (RSM) to locate the optimum separation conditions for each stationary phase. The experimental procedure was identical for both stationary phases, but their respective experimental domains were different. The response functions were peak resolution and peak efficiency. This procedure enables specific optimal experimental conditions to be identified for each of the two stationary phases. The optimal conditions identified for the separation on the phenyl stationary phase were to use 50% ACN, 20% 50 mM Tris(hydroxymethyl)aminomethane (TRIS) pH 7.5, 30% H(2)O as BGE, operating at 20 degrees C and 20 kV high voltage. For the C(18) stationary phase optimal separation was achieved using a BGE with 80% ACN, 20% 30 mM TRIS pH 8.5, again operating at 20 degrees C and 20 kV high voltage. Results show that the phenyl stationary phase is better suited for the separation of basic, hydrophilic peptides.
Related Concept Videos
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Electrophoresis: Overview
There...
Capillary Electrophoresis: Instrumentation
Ion-Exchange Chromatography
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...