Phase-Resolved Functional Lung MRI for Pulmonary Ventilation and Perfusion (V/Q) Assessment
Published on: August 9, 2024
Impact of lung volume on MR signal intensity changes of the lung parenchyma
Alexander A Bankier1, Carl R O'Donnell, Vu M Mai
1Department of Radiology, University of Vienna, Vienna, Austria. alexander.bankier@univie.ac.at
Purpose:
To test the hypothesis that, in magnetic resonance (MR) imaging of healthy individuals, equal relative changes in lung volume cause equal relative changes in MR signal intensity of the lung parenchyma.
Materials And Methods:
In two experimental runs, 10 volunteers underwent spirometrically monitored MR imaging of the lungs, with MR images acquired at 10 incremental lung volumes ranging from total lung capacity to 10% above residual volume. Average signal intensity, signal variability, and signal intensity integrals were calculated for each volunteer and for each lung volume. The effect of lung volume on signal intensity was quantified using linear regression analysis complemented by the runs test. Slopes and intercepts of regression lines were compared with an analysis of covariance. Slopes of the lines of best fit for lung volumes and signal intensities from the two runs were compared to the slope of the line of identity. Comparisons between the two runs were visualized using Bland and Altman plots.
Results:
The slopes of the 10 individual regression lines yielded no significant differences (F = 1.703, P = 0.101; F = 1.321, P = 0.239). The common slopes were -0.556 +/- 0.027 (P = 0.0001) for the first and -0.597 +/- 0.0031 (P = 0.0001) for the second experimental run. Both slopes displayed no significant nonlinearity (P = 0.419 and P = 0.067). There was a strong association between changes in lung volumes (rs = 0.991, P = 0.0001) and changes in signal intensity (rs = 0.889, P = 0.0001) in the two experimental runs. Lines of best fit for lung volume and signal intensities were not significantly different from the slope of the line of identity (P = 0.321 and P = 0.212, respectively).
Conclusion:
Equal changes in lung volume cause equal changes in MR signal intensity of the lung parenchyma. This linear and reproducible phenomenon could be helpful in comparing pulmonary MR signal intensity between individuals.
Related Concept Videos
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs during...