The case of the floating gel
R Srivastava1, M J Murphy, J Card
1Department of Biochemical Medicine, Ninewells Hospital, Dundee DD1 9SY, UK. rajeev.srivastava@tuht.scot.nhs.uk
In patients with chronic renal failure, blood samples for laboratory analysis are often taken via dialysis catheters. This report describes a case of gross spurious hypernatraemia in a blood sample collected from a patient undergoing haemodialysis. After centrifugation of the blood sample in question, the separator gel formed the topmost layer, with the serum in the middle and the clot at the bottom. Subsequent analysis of the serum showed severe hypernatraemia (serum sodium, 744 mmol/litre). It was established that the blood sample had been taken from the patient's dialysis catheter into which 3 ml of Citra-Lock (46.7% trisodium citrate) had been instilled previously as a "catheter locking" solution. The hypernatraemia seen in this case was recognised immediately as an artefact, but it was found that even minimal contamination of blood samples with Citra-Lock may significantly affect sodium concentrations. This contamination may be missed, with potentially adverse consequences for patient management.
In patients with chronic renal failure, blood samples for laboratory analysis are often taken via dialysis catheters. This report describes a case of gross spurious hypernatraemia in a blood sample collected from a patient undergoing haemodialysis. After centrifugation of the blood sample in question, the separator gel formed the topmost layer, with the serum in the middle and the clot at the bottom. Subsequent analysis of the serum showed severe hypernatraemia (serum sodium, 744 mmol/litre). It was established that the blood sample had been taken from the patient's dialysis catheter into which 3 ml of Citra-Lock (46.7% trisodium citrate) had been instilled previously as a "catheter locking" solution. The hypernatraemia seen in this case was recognised immediately as an artefact, but it was found that even minimal contamination of blood samples with Citra-Lock may significantly affect sodium concentrations. This contamination may be missed, with potentially adverse consequences for patient management.
More Related Videos
13:30A Novel Method for Localizing Reporter Fluorescent Beads Near the Cell Culture Surface for Traction Force Microscopy
Published on: September 16, 2014
08:29An Open Source Technology Platform to Manufacture Hydrogel-Based 3D Culture Models in an Automated and Standardized Fashion
Published on: March 31, 2022
Related Concept Videos
DNA Agarose Gel Electrophoresis
Gel extraction follows five major steps: running gel electrophoresis to separate fragments, isolating the individual bands, extracting DNA from those bands, and removing the dye and salts from the extracted mixture to obtain pure DNA.
In cloning experiments, both the insert and vector DNA...
Two-dimensional Gel Electrophoresis
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such as cells...